XML Markup for maintenance management of critical care medical devices

Preventive maintenance of biomedical devices is of particular concern to avoid failures and breakdowns, especially for critical care and life supporting devices. Signs of potential failures are not always visible and so, they should be inspected and tested periodically using the appropriate technolo...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Escobar, P., Fresno, Mariana del, Massa, José M., Formica, M.
Formato: Objeto de conferencia
Lenguaje:Inglés
Publicado: 2015
Materias:
Acceso en línea:http://sedici.unlp.edu.ar/handle/10915/54841
http://44jaiio.sadio.org.ar/sites/default/files/cais158-165.pdf
Aporte de:
id I19-R120-10915-54841
record_format dspace
institution Universidad Nacional de La Plata
institution_str I-19
repository_str R-120
collection SEDICI (UNLP)
language Inglés
topic Ciencias Informáticas
XML Markup language
digital signature
medical devices
patient simulator
spellingShingle Ciencias Informáticas
XML Markup language
digital signature
medical devices
patient simulator
Escobar, P.
Fresno, Mariana del
Massa, José M.
Formica, M.
XML Markup for maintenance management of critical care medical devices
topic_facet Ciencias Informáticas
XML Markup language
digital signature
medical devices
patient simulator
description Preventive maintenance of biomedical devices is of particular concern to avoid failures and breakdowns, especially for critical care and life supporting devices. Signs of potential failures are not always visible and so, they should be inspected and tested periodically using the appropriate technology. Patient simulators have become one of the essential tools for any biomedical department on every health institution, but its cost is still high to be afforded by everyone. The Labview interactive virtual instrument SIMPAC, a simple PC-based patient simulator, showed to be a low cost powerful tool for simulation of healthy and pathological conditions using signals repositories of different biomedical devices such as EEG, ECG, etc., and also to record the output signals of devices like pacemakers, defibrillators, etc. Here we present an enhancement of the tool which consists of adding a secure reporting feature using XML for presenting tests results, applying digital signature for granting report integrity, assuring this way that reports can not be altered by intentional or accidental manipulation of the data contained on it, according to the terms of the medical technology law. In addition, SIMPAC brings a low cost solution for teaching and practical purposes.
format Objeto de conferencia
Objeto de conferencia
author Escobar, P.
Fresno, Mariana del
Massa, José M.
Formica, M.
author_facet Escobar, P.
Fresno, Mariana del
Massa, José M.
Formica, M.
author_sort Escobar, P.
title XML Markup for maintenance management of critical care medical devices
title_short XML Markup for maintenance management of critical care medical devices
title_full XML Markup for maintenance management of critical care medical devices
title_fullStr XML Markup for maintenance management of critical care medical devices
title_full_unstemmed XML Markup for maintenance management of critical care medical devices
title_sort xml markup for maintenance management of critical care medical devices
publishDate 2015
url http://sedici.unlp.edu.ar/handle/10915/54841
http://44jaiio.sadio.org.ar/sites/default/files/cais158-165.pdf
work_keys_str_mv AT escobarp xmlmarkupformaintenancemanagementofcriticalcaremedicaldevices
AT fresnomarianadel xmlmarkupformaintenancemanagementofcriticalcaremedicaldevices
AT massajosem xmlmarkupformaintenancemanagementofcriticalcaremedicaldevices
AT formicam xmlmarkupformaintenancemanagementofcriticalcaremedicaldevices
bdutipo_str Repositorios
_version_ 1764820476808396805