Sequential <i>in situ</i> STM imaging of electrodissolving copper in different aqueous acid solutions
The dynamics of Cu surfaces immersed in either aqueous HClO<sub>4</sub> or H<sub>2</sub>SO<sub>4</sub> solution under galvanostatic conditions at room temperature was studied by in situ scanning tunneling microscopy (STM) sequential imaging. The mobile interface d...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | Articulo |
Lenguaje: | Inglés |
Publicado: |
1998
|
Materias: | |
Acceso en línea: | http://sedici.unlp.edu.ar/handle/10915/126571 https://www.sciencedirect.com/science/article/abs/pii/S0013468697002223 |
Aporte de: |
id |
I19-R120-10915-126571 |
---|---|
record_format |
dspace |
institution |
Universidad Nacional de La Plata |
institution_str |
I-19 |
repository_str |
R-120 |
collection |
SEDICI (UNLP) |
language |
Inglés |
topic |
Ciencias Exactas Química scanning tunneling microscopy electrodissolving copper |
spellingShingle |
Ciencias Exactas Química scanning tunneling microscopy electrodissolving copper Vela, María Elena Andreasen, Gustavo Aziz, S. G. Salvarezza, Roberto Carlos Arvia, Alejandro Jorge Sequential <i>in situ</i> STM imaging of electrodissolving copper in different aqueous acid solutions |
topic_facet |
Ciencias Exactas Química scanning tunneling microscopy electrodissolving copper |
description |
The dynamics of Cu surfaces immersed in either aqueous HClO<sub>4</sub> or H<sub>2</sub>SO<sub>4</sub> solution under galvanostatic conditions at room temperature was studied by in situ scanning tunneling microscopy (STM) sequential imaging. The mobile interface depends considerably on the apparent current density (j) applied to the specimen. At j = 0, the Cu topography turns out to be highly dynamic as mass transport among different domains takes place. Conversely, for j = 6 μA cm<sup>−2</sup> an inhomogeneous attack of the Cu surface leading to a remarkable increase in roughness and to the formation of etched pits at certain surface domains can be observed. Etched pit domains drive the mobile interface to an unstable regime. The addition of HCl to those acid solutions to reach concentrations higher than 10<sup>−2</sup> M leads to the formation of a Cu<sub>2</sub>Cl<sub>2</sub> layer. |
format |
Articulo Articulo |
author |
Vela, María Elena Andreasen, Gustavo Aziz, S. G. Salvarezza, Roberto Carlos Arvia, Alejandro Jorge |
author_facet |
Vela, María Elena Andreasen, Gustavo Aziz, S. G. Salvarezza, Roberto Carlos Arvia, Alejandro Jorge |
author_sort |
Vela, María Elena |
title |
Sequential <i>in situ</i> STM imaging of electrodissolving copper in different aqueous acid solutions |
title_short |
Sequential <i>in situ</i> STM imaging of electrodissolving copper in different aqueous acid solutions |
title_full |
Sequential <i>in situ</i> STM imaging of electrodissolving copper in different aqueous acid solutions |
title_fullStr |
Sequential <i>in situ</i> STM imaging of electrodissolving copper in different aqueous acid solutions |
title_full_unstemmed |
Sequential <i>in situ</i> STM imaging of electrodissolving copper in different aqueous acid solutions |
title_sort |
sequential <i>in situ</i> stm imaging of electrodissolving copper in different aqueous acid solutions |
publishDate |
1998 |
url |
http://sedici.unlp.edu.ar/handle/10915/126571 https://www.sciencedirect.com/science/article/abs/pii/S0013468697002223 |
work_keys_str_mv |
AT velamariaelena sequentialiinsituistmimagingofelectrodissolvingcopperindifferentaqueousacidsolutions AT andreasengustavo sequentialiinsituistmimagingofelectrodissolvingcopperindifferentaqueousacidsolutions AT azizsg sequentialiinsituistmimagingofelectrodissolvingcopperindifferentaqueousacidsolutions AT salvarezzarobertocarlos sequentialiinsituistmimagingofelectrodissolvingcopperindifferentaqueousacidsolutions AT arviaalejandrojorge sequentialiinsituistmimagingofelectrodissolvingcopperindifferentaqueousacidsolutions |
bdutipo_str |
Repositorios |
_version_ |
1764820450881306626 |