Diagnostics of cutting arc plasmas
An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (includin...
Guardado en:
Autores principales: | , |
---|---|
Formato: | CONF |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto |
Aporte de: |
id |
todo:paper_17426588_v511_n1_p_Prevosto |
---|---|
record_format |
dspace |
spelling |
todo:paper_17426588_v511_n1_p_Prevosto2023-10-03T16:30:55Z Diagnostics of cutting arc plasmas Prevosto, L. Kelly, H. Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (including the calculation assumptions) are given. Fil:Kelly, H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. CONF info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles |
spellingShingle |
Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles Prevosto, L. Kelly, H. Diagnostics of cutting arc plasmas |
topic_facet |
Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles |
description |
An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (including the calculation assumptions) are given. |
format |
CONF |
author |
Prevosto, L. Kelly, H. |
author_facet |
Prevosto, L. Kelly, H. |
author_sort |
Prevosto, L. |
title |
Diagnostics of cutting arc plasmas |
title_short |
Diagnostics of cutting arc plasmas |
title_full |
Diagnostics of cutting arc plasmas |
title_fullStr |
Diagnostics of cutting arc plasmas |
title_full_unstemmed |
Diagnostics of cutting arc plasmas |
title_sort |
diagnostics of cutting arc plasmas |
url |
http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto |
work_keys_str_mv |
AT prevostol diagnosticsofcuttingarcplasmas AT kellyh diagnosticsofcuttingarcplasmas |
_version_ |
1782030200475746304 |