Diagnostics of cutting arc plasmas

An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (includin...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Prevosto, L., Kelly, H.
Formato: CONF
Materias:
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto
Aporte de:
id todo:paper_17426588_v511_n1_p_Prevosto
record_format dspace
spelling todo:paper_17426588_v511_n1_p_Prevosto2023-10-03T16:30:55Z Diagnostics of cutting arc plasmas Prevosto, L. Kelly, H. Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (including the calculation assumptions) are given. Fil:Kelly, H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. CONF info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Physics
Arc plasma
Cutting torch
High energy densities
Nozzle exits
Set-ups
Nozzles
spellingShingle Physics
Arc plasma
Cutting torch
High energy densities
Nozzle exits
Set-ups
Nozzles
Prevosto, L.
Kelly, H.
Diagnostics of cutting arc plasmas
topic_facet Physics
Arc plasma
Cutting torch
High energy densities
Nozzle exits
Set-ups
Nozzles
description An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (including the calculation assumptions) are given.
format CONF
author Prevosto, L.
Kelly, H.
author_facet Prevosto, L.
Kelly, H.
author_sort Prevosto, L.
title Diagnostics of cutting arc plasmas
title_short Diagnostics of cutting arc plasmas
title_full Diagnostics of cutting arc plasmas
title_fullStr Diagnostics of cutting arc plasmas
title_full_unstemmed Diagnostics of cutting arc plasmas
title_sort diagnostics of cutting arc plasmas
url http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto
work_keys_str_mv AT prevostol diagnosticsofcuttingarcplasmas
AT kellyh diagnosticsofcuttingarcplasmas
_version_ 1782030200475746304