Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors

We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measur...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Rovero, A.C., Bauleo, P., Brack, J.T., Harton, J.L., Knapik, R.
Formato: JOUR
Materias:
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero
Aporte de:
id todo:paper_09276505_v31_n4_p305_Rovero
record_format dspace
spelling todo:paper_09276505_v31_n4_p305_Rovero2023-10-03T15:46:57Z Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors Rovero, A.C. Bauleo, P. Brack, J.T. Harton, J.L. Knapik, R. Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch-filters were used as the light source for the calibration device. The overall uncertainty is 5%. © 2009 Elsevier B.V. All rights reserved. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Auger Observatory
Calibration
Cosmic ray
Extensive air shower
Fluorescence detectors
At wavelengths
Auger Observatory
Cosmic ray
Detector components
Extensive air shower
Fluorescence detectors
Multi wavelengths
Pierre Auger observatories
Relative spectral response
Augers
Buildings
Calibration
Cosmic rays
Cosmology
Detectors
Light
Light sources
Notch filters
Observatories
Particle detectors
Xenon
Fluorescence
spellingShingle Auger Observatory
Calibration
Cosmic ray
Extensive air shower
Fluorescence detectors
At wavelengths
Auger Observatory
Cosmic ray
Detector components
Extensive air shower
Fluorescence detectors
Multi wavelengths
Pierre Auger observatories
Relative spectral response
Augers
Buildings
Calibration
Cosmic rays
Cosmology
Detectors
Light
Light sources
Notch filters
Observatories
Particle detectors
Xenon
Fluorescence
Rovero, A.C.
Bauleo, P.
Brack, J.T.
Harton, J.L.
Knapik, R.
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors
topic_facet Auger Observatory
Calibration
Cosmic ray
Extensive air shower
Fluorescence detectors
At wavelengths
Auger Observatory
Cosmic ray
Detector components
Extensive air shower
Fluorescence detectors
Multi wavelengths
Pierre Auger observatories
Relative spectral response
Augers
Buildings
Calibration
Cosmic rays
Cosmology
Detectors
Light
Light sources
Notch filters
Observatories
Particle detectors
Xenon
Fluorescence
description We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch-filters were used as the light source for the calibration device. The overall uncertainty is 5%. © 2009 Elsevier B.V. All rights reserved.
format JOUR
author Rovero, A.C.
Bauleo, P.
Brack, J.T.
Harton, J.L.
Knapik, R.
author_facet Rovero, A.C.
Bauleo, P.
Brack, J.T.
Harton, J.L.
Knapik, R.
author_sort Rovero, A.C.
title Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors
title_short Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors
title_full Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors
title_fullStr Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors
title_full_unstemmed Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors
title_sort multi-wavelength calibration procedure for the pierre auger observatory fluorescence detectors
url http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero
work_keys_str_mv AT roveroac multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors
AT bauleop multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors
AT brackjt multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors
AT hartonjl multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors
AT knapikr multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors
_version_ 1782025274081148928