Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors
We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measur...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | JOUR |
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero |
Aporte de: |
id |
todo:paper_09276505_v31_n4_p305_Rovero |
---|---|
record_format |
dspace |
spelling |
todo:paper_09276505_v31_n4_p305_Rovero2023-10-03T15:46:57Z Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors Rovero, A.C. Bauleo, P. Brack, J.T. Harton, J.L. Knapik, R. Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch-filters were used as the light source for the calibration device. The overall uncertainty is 5%. © 2009 Elsevier B.V. All rights reserved. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence |
spellingShingle |
Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence Rovero, A.C. Bauleo, P. Brack, J.T. Harton, J.L. Knapik, R. Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
topic_facet |
Auger Observatory Calibration Cosmic ray Extensive air shower Fluorescence detectors At wavelengths Auger Observatory Cosmic ray Detector components Extensive air shower Fluorescence detectors Multi wavelengths Pierre Auger observatories Relative spectral response Augers Buildings Calibration Cosmic rays Cosmology Detectors Light Light sources Notch filters Observatories Particle detectors Xenon Fluorescence |
description |
We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch-filters were used as the light source for the calibration device. The overall uncertainty is 5%. © 2009 Elsevier B.V. All rights reserved. |
format |
JOUR |
author |
Rovero, A.C. Bauleo, P. Brack, J.T. Harton, J.L. Knapik, R. |
author_facet |
Rovero, A.C. Bauleo, P. Brack, J.T. Harton, J.L. Knapik, R. |
author_sort |
Rovero, A.C. |
title |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_short |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_full |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_fullStr |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_full_unstemmed |
Multi-wavelength calibration procedure for the pierre Auger Observatory Fluorescence Detectors |
title_sort |
multi-wavelength calibration procedure for the pierre auger observatory fluorescence detectors |
url |
http://hdl.handle.net/20.500.12110/paper_09276505_v31_n4_p305_Rovero |
work_keys_str_mv |
AT roveroac multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors AT bauleop multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors AT brackjt multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors AT hartonjl multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors AT knapikr multiwavelengthcalibrationprocedureforthepierreaugerobservatoryfluorescencedetectors |
_version_ |
1782025274081148928 |