Soft-x-ray interferometer for single-shot laser linewidth measurements
A soft-x-ray Mach-Zehnder interferometer configuration that makes use of the time delay introduced by diffraction gratings to conduct single-shot measurements of the linewidth of soft-x-ray laser amplifiers is proposed and analyzed. The scheme was experimentally demonstrated in the near-IR region of...
Guardado en:
| Autores principales: | , , , |
|---|---|
| Formato: | JOUR |
| Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_01469592_v21_n13_p955_Chilla |
| Aporte de: |
| id |
todo:paper_01469592_v21_n13_p955_Chilla |
|---|---|
| record_format |
dspace |
| spelling |
todo:paper_01469592_v21_n13_p955_Chilla2023-10-03T15:00:18Z Soft-x-ray interferometer for single-shot laser linewidth measurements Chilla, J.L.A. Rocca, J.J. Martinez, O.E. Marconi, M.C. A soft-x-ray Mach-Zehnder interferometer configuration that makes use of the time delay introduced by diffraction gratings to conduct single-shot measurements of the linewidth of soft-x-ray laser amplifiers is proposed and analyzed. The scheme was experimentally demonstrated in the near-IR region of the spectrum by measurement of the mode separation of a semiconductor laser. A symmetric configuration with compensated time delays that can be implemented for plasma diagnostics and for evaluating soft-x-ray optics is also discussed. © 1996 Optical Society of America. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_01469592_v21_n13_p955_Chilla |
| institution |
Universidad de Buenos Aires |
| institution_str |
I-28 |
| repository_str |
R-134 |
| collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
| description |
A soft-x-ray Mach-Zehnder interferometer configuration that makes use of the time delay introduced by diffraction gratings to conduct single-shot measurements of the linewidth of soft-x-ray laser amplifiers is proposed and analyzed. The scheme was experimentally demonstrated in the near-IR region of the spectrum by measurement of the mode separation of a semiconductor laser. A symmetric configuration with compensated time delays that can be implemented for plasma diagnostics and for evaluating soft-x-ray optics is also discussed. © 1996 Optical Society of America. |
| format |
JOUR |
| author |
Chilla, J.L.A. Rocca, J.J. Martinez, O.E. Marconi, M.C. |
| spellingShingle |
Chilla, J.L.A. Rocca, J.J. Martinez, O.E. Marconi, M.C. Soft-x-ray interferometer for single-shot laser linewidth measurements |
| author_facet |
Chilla, J.L.A. Rocca, J.J. Martinez, O.E. Marconi, M.C. |
| author_sort |
Chilla, J.L.A. |
| title |
Soft-x-ray interferometer for single-shot laser linewidth measurements |
| title_short |
Soft-x-ray interferometer for single-shot laser linewidth measurements |
| title_full |
Soft-x-ray interferometer for single-shot laser linewidth measurements |
| title_fullStr |
Soft-x-ray interferometer for single-shot laser linewidth measurements |
| title_full_unstemmed |
Soft-x-ray interferometer for single-shot laser linewidth measurements |
| title_sort |
soft-x-ray interferometer for single-shot laser linewidth measurements |
| url |
http://hdl.handle.net/20.500.12110/paper_01469592_v21_n13_p955_Chilla |
| work_keys_str_mv |
AT chillajla softxrayinterferometerforsingleshotlaserlinewidthmeasurements AT roccajj softxrayinterferometerforsingleshotlaserlinewidthmeasurements AT martinezoe softxrayinterferometerforsingleshotlaserlinewidthmeasurements AT marconimc softxrayinterferometerforsingleshotlaserlinewidthmeasurements |
| _version_ |
1807321919578439680 |