A new heterodyne-beat circuit for the determination of static permittivity
A greatly improved heterodyne-beat oscillator was built using integrated circuits, to measure static permittivity of liquid samples. Frequency variation of the oscillator is of less than 0.7 Hz/h; that corresponds to a capacity variation of less than 0.005 pF/h. Permittivity can be measured with a p...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | JOUR |
Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_00346748_v66_n4_p3067_Castex |
Aporte de: |
id |
todo:paper_00346748_v66_n4_p3067_Castex |
---|---|
record_format |
dspace |
spelling |
todo:paper_00346748_v66_n4_p3067_Castex2023-10-03T14:46:07Z A new heterodyne-beat circuit for the determination of static permittivity Castex, T.A. De Vivar, P.D. Paz, M.B.R. Buep, A.H. A greatly improved heterodyne-beat oscillator was built using integrated circuits, to measure static permittivity of liquid samples. Frequency variation of the oscillator is of less than 0.7 Hz/h; that corresponds to a capacity variation of less than 0.005 pF/h. Permittivity can be measured with a precision of 0.003% and an accuracy better than 0.01%. © 1995 American Institute of Physics. Fil:Castex, T.A. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Buep, A.H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_00346748_v66_n4_p3067_Castex |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
description |
A greatly improved heterodyne-beat oscillator was built using integrated circuits, to measure static permittivity of liquid samples. Frequency variation of the oscillator is of less than 0.7 Hz/h; that corresponds to a capacity variation of less than 0.005 pF/h. Permittivity can be measured with a precision of 0.003% and an accuracy better than 0.01%. © 1995 American Institute of Physics. |
format |
JOUR |
author |
Castex, T.A. De Vivar, P.D. Paz, M.B.R. Buep, A.H. |
spellingShingle |
Castex, T.A. De Vivar, P.D. Paz, M.B.R. Buep, A.H. A new heterodyne-beat circuit for the determination of static permittivity |
author_facet |
Castex, T.A. De Vivar, P.D. Paz, M.B.R. Buep, A.H. |
author_sort |
Castex, T.A. |
title |
A new heterodyne-beat circuit for the determination of static permittivity |
title_short |
A new heterodyne-beat circuit for the determination of static permittivity |
title_full |
A new heterodyne-beat circuit for the determination of static permittivity |
title_fullStr |
A new heterodyne-beat circuit for the determination of static permittivity |
title_full_unstemmed |
A new heterodyne-beat circuit for the determination of static permittivity |
title_sort |
new heterodyne-beat circuit for the determination of static permittivity |
url |
http://hdl.handle.net/20.500.12110/paper_00346748_v66_n4_p3067_Castex |
work_keys_str_mv |
AT castexta anewheterodynebeatcircuitforthedeterminationofstaticpermittivity AT devivarpd anewheterodynebeatcircuitforthedeterminationofstaticpermittivity AT pazmbr anewheterodynebeatcircuitforthedeterminationofstaticpermittivity AT buepah anewheterodynebeatcircuitforthedeterminationofstaticpermittivity AT castexta newheterodynebeatcircuitforthedeterminationofstaticpermittivity AT devivarpd newheterodynebeatcircuitforthedeterminationofstaticpermittivity AT pazmbr newheterodynebeatcircuitforthedeterminationofstaticpermittivity AT buepah newheterodynebeatcircuitforthedeterminationofstaticpermittivity |
_version_ |
1807321217087045632 |