Reduction of radiation errors in thermal conductivity measurements above 100 K

A steady-state method for thermal conductivity measurements above 100 K on poor conductors is described. Radiation errors are made negligible using a closely fitting shield with a temperature profile matched along its length to that of the sample. Calculations show that for a typical geometry, the r...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Talpe, J.H., Bekeris, V.I., Sanchez, M.J., Simonelli, G.
Formato: JOUR
Acceso en línea:http://hdl.handle.net/20.500.12110/paper_00346748_v62_n4_p1054_Talpe
Aporte de:
id todo:paper_00346748_v62_n4_p1054_Talpe
record_format dspace
spelling todo:paper_00346748_v62_n4_p1054_Talpe2023-10-03T14:46:06Z Reduction of radiation errors in thermal conductivity measurements above 100 K Talpe, J.H. Bekeris, V.I. Sanchez, M.J. Simonelli, G. A steady-state method for thermal conductivity measurements above 100 K on poor conductors is described. Radiation errors are made negligible using a closely fitting shield with a temperature profile matched along its length to that of the sample. Calculations show that for a typical geometry, the radiation error at room temperature is two or three orders of magnitude lower than for a shield kept at the sink temperature. The experimental setup is described and measurements on PMMA are reported. The results agree with measurements reported by other authors who use completely different methods. Fil:Bekeris, V.I. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Sanchez, M.J. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Simonelli, G. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_00346748_v62_n4_p1054_Talpe
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
description A steady-state method for thermal conductivity measurements above 100 K on poor conductors is described. Radiation errors are made negligible using a closely fitting shield with a temperature profile matched along its length to that of the sample. Calculations show that for a typical geometry, the radiation error at room temperature is two or three orders of magnitude lower than for a shield kept at the sink temperature. The experimental setup is described and measurements on PMMA are reported. The results agree with measurements reported by other authors who use completely different methods.
format JOUR
author Talpe, J.H.
Bekeris, V.I.
Sanchez, M.J.
Simonelli, G.
spellingShingle Talpe, J.H.
Bekeris, V.I.
Sanchez, M.J.
Simonelli, G.
Reduction of radiation errors in thermal conductivity measurements above 100 K
author_facet Talpe, J.H.
Bekeris, V.I.
Sanchez, M.J.
Simonelli, G.
author_sort Talpe, J.H.
title Reduction of radiation errors in thermal conductivity measurements above 100 K
title_short Reduction of radiation errors in thermal conductivity measurements above 100 K
title_full Reduction of radiation errors in thermal conductivity measurements above 100 K
title_fullStr Reduction of radiation errors in thermal conductivity measurements above 100 K
title_full_unstemmed Reduction of radiation errors in thermal conductivity measurements above 100 K
title_sort reduction of radiation errors in thermal conductivity measurements above 100 k
url http://hdl.handle.net/20.500.12110/paper_00346748_v62_n4_p1054_Talpe
work_keys_str_mv AT talpejh reductionofradiationerrorsinthermalconductivitymeasurementsabove100k
AT bekerisvi reductionofradiationerrorsinthermalconductivitymeasurementsabove100k
AT sanchezmj reductionofradiationerrorsinthermalconductivitymeasurementsabove100k
AT simonellig reductionofradiationerrorsinthermalconductivitymeasurementsabove100k
_version_ 1782027711360794624