Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm
A method is proposed for wavelength calibration of the reversed-optics polychromators of photodiode array spectrophotometers. The central wavelength of each diode is determined using classical line emission sources and an appropriate algorithm. The method can be used even when the light from the sli...
Guardado en:
| Autores principales: | , |
|---|---|
| Formato: | JOUR |
| Materias: | |
| Acceso en línea: | http://hdl.handle.net/20.500.12110/paper_00032654_v116_n3_p313_Berlot |
| Aporte de: |
| id |
todo:paper_00032654_v116_n3_p313_Berlot |
|---|---|
| record_format |
dspace |
| spelling |
todo:paper_00032654_v116_n3_p313_Berlot2023-10-03T13:55:38Z Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm Berlot, P.E. Locascio, G.A. article chemical analysis computer system spectrophotometry technique A method is proposed for wavelength calibration of the reversed-optics polychromators of photodiode array spectrophotometers. The central wavelength of each diode is determined using classical line emission sources and an appropriate algorithm. The method can be used even when the light from the slit image formed on the detector falls on several diodes, whether due to a large slit to diode ratio, detector window effects or other causes. Fil:Locascio, G.A. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. JOUR info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/2.5/ar http://hdl.handle.net/20.500.12110/paper_00032654_v116_n3_p313_Berlot |
| institution |
Universidad de Buenos Aires |
| institution_str |
I-28 |
| repository_str |
R-134 |
| collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
| topic |
article chemical analysis computer system spectrophotometry technique |
| spellingShingle |
article chemical analysis computer system spectrophotometry technique Berlot, P.E. Locascio, G.A. Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm |
| topic_facet |
article chemical analysis computer system spectrophotometry technique |
| description |
A method is proposed for wavelength calibration of the reversed-optics polychromators of photodiode array spectrophotometers. The central wavelength of each diode is determined using classical line emission sources and an appropriate algorithm. The method can be used even when the light from the slit image formed on the detector falls on several diodes, whether due to a large slit to diode ratio, detector window effects or other causes. |
| format |
JOUR |
| author |
Berlot, P.E. Locascio, G.A. |
| author_facet |
Berlot, P.E. Locascio, G.A. |
| author_sort |
Berlot, P.E. |
| title |
Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm |
| title_short |
Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm |
| title_full |
Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm |
| title_fullStr |
Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm |
| title_full_unstemmed |
Ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. A practical computer algorithm |
| title_sort |
ultraviolet-visible photodiode array spectrophotometer wavelength calibration method. a practical computer algorithm |
| url |
http://hdl.handle.net/20.500.12110/paper_00032654_v116_n3_p313_Berlot |
| work_keys_str_mv |
AT berlotpe ultravioletvisiblephotodiodearrayspectrophotometerwavelengthcalibrationmethodapracticalcomputeralgorithm AT locascioga ultravioletvisiblephotodiodearrayspectrophotometerwavelengthcalibrationmethodapracticalcomputeralgorithm |
| _version_ |
1807324400415932416 |