Towards broadening thermospray flame furnace atomic absorption spectrometry: Influence of organic solvents on the analytical signal of magnesium

This study demonstrates the influence of the solvent when thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) is employed for the determination of elements of low volatility, taking magnesium (Mg) as leading case. Several organic solvents/water solutions of different characteristics...

Descripción completa

Guardado en:
Detalles Bibliográficos
Publicado: 2015
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_22141812_v4_n_p1_Morzan
http://hdl.handle.net/20.500.12110/paper_22141812_v4_n_p1_Morzan
Aporte de:
id paper:paper_22141812_v4_n_p1_Morzan
record_format dspace
spelling paper:paper_22141812_v4_n_p1_Morzan2023-06-08T16:35:18Z Towards broadening thermospray flame furnace atomic absorption spectrometry: Influence of organic solvents on the analytical signal of magnesium Cell temperature Droplet size Magnesium determination Optimization of the analytical signal Organic solvents Thermospray This study demonstrates the influence of the solvent when thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) is employed for the determination of elements of low volatility, taking magnesium (Mg) as leading case. Several organic solvents/water solutions of different characteristics (density, surface tension, viscosity, etc.) and proportions were employed for the TS-FF-AAS analytical determination. To this end, solutions containing methanol, ethanol and isopropanol in water were assayed. Measurements were performed at different acetylene/air ratios of the combustion flame and then, the corresponding response surfaces were obtained. Methanol/water 75% v/v as carrier and a fuel rich flame were found as the most sensitive alternative.In the light of these findings and in order to explain the changes on the analytical signal, the influence of the solvent characteristics, the sample droplet size and the redox environment was studied. An estimation of the temperature of different zones of the heated flame furnace based on a modified signal ratio pyrometry method was analyzed for comparative purposes. A full discussion is provided throughout the paper.Once obtained the best conditions for analysis, Mg was determined in samples of effervescent vitamin tablets comparing two different solvents. The tablets were dissolved in methanol/water 75% v/v and ethanol/water 75% v/v and then, directly introduced in the TS device. The methanol/water 75% v/v dissolution yielded a slightly higher sensitivity when compared to ethanol/water and thus, the latter was selected due to its lower toxicity. The obtained figures of merit are: LOD (3σb): 0.021mgL-1; LOQ (10σb): 0.068mgL-1, sensitivity: 0.086Lmg-1; RSD%: 3.55, dynamic linear range 0.068-5mgL-1. Comparison of the results was performed by flame atomic absorption spectrometry (FAAS), showing a good agreement (95% confidence level, n=5). Whilst the FAAS approach needed sample mineralization as no complete solubility was attained with both alcohol/water solvents, TS allowed direct introduction of the sample with an excellent recovery of the analyte after spiking. The whole TS procedure was more economic (lower amount of reagents and wastings, lower time of operation) and faster (60h-1 sampling throughput) than FAAS.Nonetheless, the main objective of this work is to show that an analytical signal different from zero can be obtained for Mg via TS by simply choosing the adequate operational variables that allow an optimization of the mass transfer of the analyte into the atomizer and a favorable dynamics of desolvation/atomization.This approach could broad TS analytical capabilities to other elements of lower volatility as it is shown here for the case of Mg. © 2015 The Authors. 2015 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_22141812_v4_n_p1_Morzan http://hdl.handle.net/20.500.12110/paper_22141812_v4_n_p1_Morzan
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Cell temperature
Droplet size
Magnesium determination
Optimization of the analytical signal
Organic solvents
Thermospray
spellingShingle Cell temperature
Droplet size
Magnesium determination
Optimization of the analytical signal
Organic solvents
Thermospray
Towards broadening thermospray flame furnace atomic absorption spectrometry: Influence of organic solvents on the analytical signal of magnesium
topic_facet Cell temperature
Droplet size
Magnesium determination
Optimization of the analytical signal
Organic solvents
Thermospray
description This study demonstrates the influence of the solvent when thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) is employed for the determination of elements of low volatility, taking magnesium (Mg) as leading case. Several organic solvents/water solutions of different characteristics (density, surface tension, viscosity, etc.) and proportions were employed for the TS-FF-AAS analytical determination. To this end, solutions containing methanol, ethanol and isopropanol in water were assayed. Measurements were performed at different acetylene/air ratios of the combustion flame and then, the corresponding response surfaces were obtained. Methanol/water 75% v/v as carrier and a fuel rich flame were found as the most sensitive alternative.In the light of these findings and in order to explain the changes on the analytical signal, the influence of the solvent characteristics, the sample droplet size and the redox environment was studied. An estimation of the temperature of different zones of the heated flame furnace based on a modified signal ratio pyrometry method was analyzed for comparative purposes. A full discussion is provided throughout the paper.Once obtained the best conditions for analysis, Mg was determined in samples of effervescent vitamin tablets comparing two different solvents. The tablets were dissolved in methanol/water 75% v/v and ethanol/water 75% v/v and then, directly introduced in the TS device. The methanol/water 75% v/v dissolution yielded a slightly higher sensitivity when compared to ethanol/water and thus, the latter was selected due to its lower toxicity. The obtained figures of merit are: LOD (3σb): 0.021mgL-1; LOQ (10σb): 0.068mgL-1, sensitivity: 0.086Lmg-1; RSD%: 3.55, dynamic linear range 0.068-5mgL-1. Comparison of the results was performed by flame atomic absorption spectrometry (FAAS), showing a good agreement (95% confidence level, n=5). Whilst the FAAS approach needed sample mineralization as no complete solubility was attained with both alcohol/water solvents, TS allowed direct introduction of the sample with an excellent recovery of the analyte after spiking. The whole TS procedure was more economic (lower amount of reagents and wastings, lower time of operation) and faster (60h-1 sampling throughput) than FAAS.Nonetheless, the main objective of this work is to show that an analytical signal different from zero can be obtained for Mg via TS by simply choosing the adequate operational variables that allow an optimization of the mass transfer of the analyte into the atomizer and a favorable dynamics of desolvation/atomization.This approach could broad TS analytical capabilities to other elements of lower volatility as it is shown here for the case of Mg. © 2015 The Authors.
title Towards broadening thermospray flame furnace atomic absorption spectrometry: Influence of organic solvents on the analytical signal of magnesium
title_short Towards broadening thermospray flame furnace atomic absorption spectrometry: Influence of organic solvents on the analytical signal of magnesium
title_full Towards broadening thermospray flame furnace atomic absorption spectrometry: Influence of organic solvents on the analytical signal of magnesium
title_fullStr Towards broadening thermospray flame furnace atomic absorption spectrometry: Influence of organic solvents on the analytical signal of magnesium
title_full_unstemmed Towards broadening thermospray flame furnace atomic absorption spectrometry: Influence of organic solvents on the analytical signal of magnesium
title_sort towards broadening thermospray flame furnace atomic absorption spectrometry: influence of organic solvents on the analytical signal of magnesium
publishDate 2015
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_22141812_v4_n_p1_Morzan
http://hdl.handle.net/20.500.12110/paper_22141812_v4_n_p1_Morzan
_version_ 1768543441965285376