Diagnostics of cutting arc plasmas
An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (includin...
Guardado en:
Autor principal: | |
---|---|
Publicado: |
2014
|
Materias: | |
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_17426588_v511_n1_p_Prevosto http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto |
Aporte de: |
id |
paper:paper_17426588_v511_n1_p_Prevosto |
---|---|
record_format |
dspace |
spelling |
paper:paper_17426588_v511_n1_p_Prevosto2023-06-08T16:27:31Z Diagnostics of cutting arc plasmas Kelly, Héctor Juan Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (including the calculation assumptions) are given. Fil:Kelly, H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2014 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_17426588_v511_n1_p_Prevosto http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles |
spellingShingle |
Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles Kelly, Héctor Juan Diagnostics of cutting arc plasmas |
topic_facet |
Physics Arc plasma Cutting torch High energy densities Nozzle exits Set-ups Nozzles |
description |
An over-view of several remote and invasive diagnostics to characterize cutting arcs at the nozzle exit-anode gap as well as inside the nozzle is reported. A briefly description of the experimental set-ups, together with the main results obtained in a 30 A high-energy density cutting torch (including the calculation assumptions) are given. |
author |
Kelly, Héctor Juan |
author_facet |
Kelly, Héctor Juan |
author_sort |
Kelly, Héctor Juan |
title |
Diagnostics of cutting arc plasmas |
title_short |
Diagnostics of cutting arc plasmas |
title_full |
Diagnostics of cutting arc plasmas |
title_fullStr |
Diagnostics of cutting arc plasmas |
title_full_unstemmed |
Diagnostics of cutting arc plasmas |
title_sort |
diagnostics of cutting arc plasmas |
publishDate |
2014 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_17426588_v511_n1_p_Prevosto http://hdl.handle.net/20.500.12110/paper_17426588_v511_n1_p_Prevosto |
work_keys_str_mv |
AT kellyhectorjuan diagnosticsofcuttingarcplasmas |
_version_ |
1768546370060288000 |