Anamorphic cameras for stellar spectrographs

When image slicers are used, the length of the lines in high dispersion stellar spectra may become longer than desirable. Then it is necessary to demagnify the line length to reduce the exposure time. In this paper line profiles are obtained for anamorphic cameras and for the Bowen lens. If a refere...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Simon, Juan Miguel, Simón, María C.
Publicado: 1980
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1559128X_v19_n1_p61_Simon
http://hdl.handle.net/20.500.12110/paper_1559128X_v19_n1_p61_Simon
Aporte de:
id paper:paper_1559128X_v19_n1_p61_Simon
record_format dspace
spelling paper:paper_1559128X_v19_n1_p61_Simon2023-06-08T16:23:25Z Anamorphic cameras for stellar spectrographs Simon, Juan Miguel Simón, María C. SPECTROGRAPHS CAMERAS When image slicers are used, the length of the lines in high dispersion stellar spectra may become longer than desirable. Then it is necessary to demagnify the line length to reduce the exposure time. In this paper line profiles are obtained for anamorphic cameras and for the Bowen lens. If a reference spectrum is required or the camera is of small focal ratio (F/D < 10), anamorphic cameras are desirable. Otherwise the Bowen lens gives better results, but other considerations must be taken into account too. © 1980, Optical Society of America. Fil:Simon, J.M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Simon, M.C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 1980 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1559128X_v19_n1_p61_Simon http://hdl.handle.net/20.500.12110/paper_1559128X_v19_n1_p61_Simon
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic SPECTROGRAPHS
CAMERAS
spellingShingle SPECTROGRAPHS
CAMERAS
Simon, Juan Miguel
Simón, María C.
Anamorphic cameras for stellar spectrographs
topic_facet SPECTROGRAPHS
CAMERAS
description When image slicers are used, the length of the lines in high dispersion stellar spectra may become longer than desirable. Then it is necessary to demagnify the line length to reduce the exposure time. In this paper line profiles are obtained for anamorphic cameras and for the Bowen lens. If a reference spectrum is required or the camera is of small focal ratio (F/D < 10), anamorphic cameras are desirable. Otherwise the Bowen lens gives better results, but other considerations must be taken into account too. © 1980, Optical Society of America.
author Simon, Juan Miguel
Simón, María C.
author_facet Simon, Juan Miguel
Simón, María C.
author_sort Simon, Juan Miguel
title Anamorphic cameras for stellar spectrographs
title_short Anamorphic cameras for stellar spectrographs
title_full Anamorphic cameras for stellar spectrographs
title_fullStr Anamorphic cameras for stellar spectrographs
title_full_unstemmed Anamorphic cameras for stellar spectrographs
title_sort anamorphic cameras for stellar spectrographs
publishDate 1980
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_1559128X_v19_n1_p61_Simon
http://hdl.handle.net/20.500.12110/paper_1559128X_v19_n1_p61_Simon
work_keys_str_mv AT simonjuanmiguel anamorphiccamerasforstellarspectrographs
AT simonmariac anamorphiccamerasforstellarspectrographs
_version_ 1768541723706785792