Characterization of a quarter torus filter for vacuum arc ion flux transmission

Measurements on the ion flux transmission in a magnetically filtered d-c vacuum arc are presented. The device includes a metallic plasma-generating chamber with water-cooled electrodes coupled to a substrate chamber through a quarter-torus magnetic filter. It is employed a Copper cathode (6 cm in di...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kelly, Héctor Juan, Marquez, Adriana B., Pirrera, Mónica Beatriz
Publicado: 2004
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_01039733_v34_n4B_p1513_Kelly
http://hdl.handle.net/20.500.12110/paper_01039733_v34_n4B_p1513_Kelly
Aporte de:
id paper:paper_01039733_v34_n4B_p1513_Kelly
record_format dspace
spelling paper:paper_01039733_v34_n4B_p1513_Kelly2023-06-08T15:10:27Z Characterization of a quarter torus filter for vacuum arc ion flux transmission Kelly, Héctor Juan Marquez, Adriana B. Pirrera, Mónica Beatriz Measurements on the ion flux transmission in a magnetically filtered d-c vacuum arc are presented. The device includes a metallic plasma-generating chamber with water-cooled electrodes coupled to a substrate chamber through a quarter-torus magnetic filter. It is employed a Copper cathode (6 cm in diameter) with a Copper annular anode. The filter consists in a steel cylinder 500 mm length and 100 mm inner diameter with 90° of bending angle and corrugated lateral walls, surrounded by a magnetic field generating coil. The arc is operated at a current level of 100 A, and the intensity of the filtering magnetic field was in the range 0-200 G (measured at the knee of the filter). This magnetic field is enough high so as to magnetize the electrons but not the ions. The discharge is ignited by bringing (and later removing) a tungsten striker into contact with the cathode. The arc voltage drop, the floating potentials of the filter and the plasma, and the ion current collected by probes located at different positions as functions of the magnetic field intensity are reported and compared with measurements presented in the literature with other similar devices. Fil:Kelly, H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Márquez, A. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Pirrera, M. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2004 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_01039733_v34_n4B_p1513_Kelly http://hdl.handle.net/20.500.12110/paper_01039733_v34_n4B_p1513_Kelly
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
description Measurements on the ion flux transmission in a magnetically filtered d-c vacuum arc are presented. The device includes a metallic plasma-generating chamber with water-cooled electrodes coupled to a substrate chamber through a quarter-torus magnetic filter. It is employed a Copper cathode (6 cm in diameter) with a Copper annular anode. The filter consists in a steel cylinder 500 mm length and 100 mm inner diameter with 90° of bending angle and corrugated lateral walls, surrounded by a magnetic field generating coil. The arc is operated at a current level of 100 A, and the intensity of the filtering magnetic field was in the range 0-200 G (measured at the knee of the filter). This magnetic field is enough high so as to magnetize the electrons but not the ions. The discharge is ignited by bringing (and later removing) a tungsten striker into contact with the cathode. The arc voltage drop, the floating potentials of the filter and the plasma, and the ion current collected by probes located at different positions as functions of the magnetic field intensity are reported and compared with measurements presented in the literature with other similar devices.
author Kelly, Héctor Juan
Marquez, Adriana B.
Pirrera, Mónica Beatriz
spellingShingle Kelly, Héctor Juan
Marquez, Adriana B.
Pirrera, Mónica Beatriz
Characterization of a quarter torus filter for vacuum arc ion flux transmission
author_facet Kelly, Héctor Juan
Marquez, Adriana B.
Pirrera, Mónica Beatriz
author_sort Kelly, Héctor Juan
title Characterization of a quarter torus filter for vacuum arc ion flux transmission
title_short Characterization of a quarter torus filter for vacuum arc ion flux transmission
title_full Characterization of a quarter torus filter for vacuum arc ion flux transmission
title_fullStr Characterization of a quarter torus filter for vacuum arc ion flux transmission
title_full_unstemmed Characterization of a quarter torus filter for vacuum arc ion flux transmission
title_sort characterization of a quarter torus filter for vacuum arc ion flux transmission
publishDate 2004
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_01039733_v34_n4B_p1513_Kelly
http://hdl.handle.net/20.500.12110/paper_01039733_v34_n4B_p1513_Kelly
work_keys_str_mv AT kellyhectorjuan characterizationofaquartertorusfilterforvacuumarcionfluxtransmission
AT marquezadrianab characterizationofaquartertorusfilterforvacuumarcionfluxtransmission
AT pirreramonicabeatriz characterizationofaquartertorusfilterforvacuumarcionfluxtransmission
_version_ 1768546392556437504