Fast cycle, wide temperature range a.c. susceptometer
An a.c. susceptometer of simple design, operating from 4 K to room temperature is described. The sample can be easily replaced and cooled to 4 K in less than 1 h with low helium boil-off. Measuring coils are immersed in the cryogenic bath, so that a serious source of thermal drift voltage is avoided...
Guardado en:
Autores principales: | , , , , |
---|---|
Publicado: |
1993
|
Materias: | |
Acceso en línea: | https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00112275_v33_n11_p1037_Ferrari http://hdl.handle.net/20.500.12110/paper_00112275_v33_n11_p1037_Ferrari |
Aporte de: |
id |
paper:paper_00112275_v33_n11_p1037_Ferrari |
---|---|
record_format |
dspace |
spelling |
paper:paper_00112275_v33_n11_p1037_Ferrari2023-06-08T14:34:51Z Fast cycle, wide temperature range a.c. susceptometer Ferrari, Hernán Javier Codner, Darío Gabriel Levy, Pablo Eduardo Acha, Carlos Enrique Bekeris, Victoria Isabel a.c. susceptibility cryostats design considerations Cooling Cryostats Dewars Electric coils Electric conductivity Helium Magnetic fields Magnetic variables measurement Superconducting magnets Alternating current susceptibility Alternating current susceptometer Cryogenic bath Helium boil off Measuring coils Mutual inductance Thermal drift voltage Magnetic measuring instruments An a.c. susceptometer of simple design, operating from 4 K to room temperature is described. The sample can be easily replaced and cooled to 4 K in less than 1 h with low helium boil-off. Measuring coils are immersed in the cryogenic bath, so that a serious source of thermal drift voltage is avoided. © 1993. Fil:Ferrari, H. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Codner, G. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Levy, P. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Acha, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Bekeris, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 1993 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00112275_v33_n11_p1037_Ferrari http://hdl.handle.net/20.500.12110/paper_00112275_v33_n11_p1037_Ferrari |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-134 |
collection |
Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA) |
topic |
a.c. susceptibility cryostats design considerations Cooling Cryostats Dewars Electric coils Electric conductivity Helium Magnetic fields Magnetic variables measurement Superconducting magnets Alternating current susceptibility Alternating current susceptometer Cryogenic bath Helium boil off Measuring coils Mutual inductance Thermal drift voltage Magnetic measuring instruments |
spellingShingle |
a.c. susceptibility cryostats design considerations Cooling Cryostats Dewars Electric coils Electric conductivity Helium Magnetic fields Magnetic variables measurement Superconducting magnets Alternating current susceptibility Alternating current susceptometer Cryogenic bath Helium boil off Measuring coils Mutual inductance Thermal drift voltage Magnetic measuring instruments Ferrari, Hernán Javier Codner, Darío Gabriel Levy, Pablo Eduardo Acha, Carlos Enrique Bekeris, Victoria Isabel Fast cycle, wide temperature range a.c. susceptometer |
topic_facet |
a.c. susceptibility cryostats design considerations Cooling Cryostats Dewars Electric coils Electric conductivity Helium Magnetic fields Magnetic variables measurement Superconducting magnets Alternating current susceptibility Alternating current susceptometer Cryogenic bath Helium boil off Measuring coils Mutual inductance Thermal drift voltage Magnetic measuring instruments |
description |
An a.c. susceptometer of simple design, operating from 4 K to room temperature is described. The sample can be easily replaced and cooled to 4 K in less than 1 h with low helium boil-off. Measuring coils are immersed in the cryogenic bath, so that a serious source of thermal drift voltage is avoided. © 1993. |
author |
Ferrari, Hernán Javier Codner, Darío Gabriel Levy, Pablo Eduardo Acha, Carlos Enrique Bekeris, Victoria Isabel |
author_facet |
Ferrari, Hernán Javier Codner, Darío Gabriel Levy, Pablo Eduardo Acha, Carlos Enrique Bekeris, Victoria Isabel |
author_sort |
Ferrari, Hernán Javier |
title |
Fast cycle, wide temperature range a.c. susceptometer |
title_short |
Fast cycle, wide temperature range a.c. susceptometer |
title_full |
Fast cycle, wide temperature range a.c. susceptometer |
title_fullStr |
Fast cycle, wide temperature range a.c. susceptometer |
title_full_unstemmed |
Fast cycle, wide temperature range a.c. susceptometer |
title_sort |
fast cycle, wide temperature range a.c. susceptometer |
publishDate |
1993 |
url |
https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00112275_v33_n11_p1037_Ferrari http://hdl.handle.net/20.500.12110/paper_00112275_v33_n11_p1037_Ferrari |
work_keys_str_mv |
AT ferrarihernanjavier fastcyclewidetemperaturerangeacsusceptometer AT codnerdariogabriel fastcyclewidetemperaturerangeacsusceptometer AT levypabloeduardo fastcyclewidetemperaturerangeacsusceptometer AT achacarlosenrique fastcyclewidetemperaturerangeacsusceptometer AT bekerisvictoriaisabel fastcyclewidetemperaturerangeacsusceptometer |
_version_ |
1768541780043628544 |