Harmonic state estimation on a radial distribution system with distributed generation.
In the present work, a state estimation technique is applied to calculate the amplitudes and phase angles of the harmonic currents injected at the buses of a power distribution system. To this effect, the model of a 50-Hz 13.2-kV 4-bus radial system is used. The grid (source) and a generator are con...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | Artículo publishedVersion |
Lenguaje: | Inglés Inglés |
Publicado: |
Institute Of Electrical and Electronics Engineers (IEEE), Piscataway, NJ, Estados Unidos
2018
|
Materias: | |
Acceso en línea: | http://hdl.handle.net/20.500.12272/3048 https://doi.org/10.1109/TLA.2013.6502852 |
Aporte de: |
id |
I68-R174-20.500.12272-3048 |
---|---|
record_format |
dspace |
institution |
Universidad Tecnológica Nacional |
institution_str |
I-68 |
repository_str |
R-174 |
collection |
RIA - Repositorio Institucional Abierto (UTN) |
language |
Inglés Inglés |
topic |
Harmonic distortion State estimation Power distribution Power system harmonics |
spellingShingle |
Harmonic distortion State estimation Power distribution Power system harmonics Ferreyra, Diego M. Sarmiento, Ana C. Reineri, Claudio A. Harmonic state estimation on a radial distribution system with distributed generation. |
topic_facet |
Harmonic distortion State estimation Power distribution Power system harmonics |
description |
In the present work, a state estimation technique is applied to calculate the amplitudes and phase angles of the harmonic currents injected at the buses of a power distribution system. To this effect, the model of a 50-Hz 13.2-kV 4-bus radial system is used. The grid (source) and a generator are connected at opposite ends of the system, following a configuration known as distributed generation, which is becoming quite usual nowadays. In this particular implementation, the nodal harmonic voltages are presented as the state variables instead of the harmonic currents. This follows the same structure as a traditional fundamental frequency state estimation. As a further step, the injected harmonic currents are calculated from the corresponding injected powers and nodal voltages. |
format |
Artículo publishedVersion Artículo |
author |
Ferreyra, Diego M. Sarmiento, Ana C. Reineri, Claudio A. |
author_facet |
Ferreyra, Diego M. Sarmiento, Ana C. Reineri, Claudio A. |
author_sort |
Ferreyra, Diego M. |
title |
Harmonic state estimation on a radial distribution system with distributed generation. |
title_short |
Harmonic state estimation on a radial distribution system with distributed generation. |
title_full |
Harmonic state estimation on a radial distribution system with distributed generation. |
title_fullStr |
Harmonic state estimation on a radial distribution system with distributed generation. |
title_full_unstemmed |
Harmonic state estimation on a radial distribution system with distributed generation. |
title_sort |
harmonic state estimation on a radial distribution system with distributed generation. |
publisher |
Institute Of Electrical and Electronics Engineers (IEEE), Piscataway, NJ, Estados Unidos |
publishDate |
2018 |
url |
http://hdl.handle.net/20.500.12272/3048 https://doi.org/10.1109/TLA.2013.6502852 |
work_keys_str_mv |
AT ferreyradiegom harmonicstateestimationonaradialdistributionsystemwithdistributedgeneration AT sarmientoanac harmonicstateestimationonaradialdistributionsystemwithdistributedgeneration AT reinericlaudioa harmonicstateestimationonaradialdistributionsystemwithdistributedgeneration |
bdutipo_str |
Repositorios |
_version_ |
1764820551512096768 |