Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
Purpose: To present our experience of slit-lamp laser photocoagulation with a pediatric quadraspheric contact lens for the treatment of retinopathy of prematurity (ROP). Material and methods: 8 eyes of 4 premature babies with threshold ROP were consecutively treated under general anesthesia by means...
Guardado en:
| Autores principales: | , , |
|---|---|
| Formato: | Artículo |
| Lenguaje: | Español |
| Publicado: |
2000
|
| Materias: | |
| Acceso en línea: | http://pa.bibdigital.ucc.edu.ar/3917/1/A_UrretsZavalia_UrretsZavalia_Iros.pdf |
| Aporte de: |
| id |
I38-R144-3917 |
|---|---|
| record_format |
dspace |
| spelling |
I38-R144-39172025-04-14T19:49:09Z http://pa.bibdigital.ucc.edu.ar/3917/ Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity Urrets Zavalía, Julio Urrets Zavalía, Enrique Alberto Iros, M. RE Oftalmología Purpose: To present our experience of slit-lamp laser photocoagulation with a pediatric quadraspheric contact lens for the treatment of retinopathy of prematurity (ROP). Material and methods: 8 eyes of 4 premature babies with threshold ROP were consecutively treated under general anesthesia by means of blue-green argon laser photocoagulation delivered through a table mounted slit-lamp and a wide field contact lens specially designed for infants. Three of the treated eyes had a zone, disease, 2 a posterior zone II disease and 3 a zone II disease. Mean follow-up was 13 months. Results: Early complete regression of the neovascular proliferations and plus disease was observed in all the treated eyes (100%) without apparent sequela. In only one eye that had zone I disease a mild and small peripheral vitreous hemorrhage was observed. Neither cataract nor posterior synechia was observed. A discrete and transient badly hypothermia occurred only in one case. Comments and conclusions: This study shows the efficacy and precision of slit-lamp argon laser photocoagulation through a quadraspheric contact lens in ROP, with a very low rate of complications, and with a magnificent and comfortable visualization of all the structures to be treated. Each retinal burn was easily and very precisely placed from the ridge to the ora serrata in 360°with only a slight to moderate tilting of the wide field lens and without the need of scleral depression. 2000-04-30 info:eu-repo/semantics/article info:eu-repo/semantics/closedAccess application/pdf spa http://pa.bibdigital.ucc.edu.ar/3917/1/A_UrretsZavalia_UrretsZavalia_Iros.pdf Urrets Zavalía, Julio ORCID: https://orcid.org/0000-0003-2267-2783 <https://orcid.org/0000-0003-2267-2783>, Urrets Zavalía, Enrique Alberto and Iros, M. (2000) Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity. Journal Francais d'Ophtalmologie, 23 (4). pp. 361-363. ISSN 0181-5512 https://www.scopus.com/record/display.uri?eid=2-s2.0-0034042399&origin=resultslist&sort=plf-f&src=s&nlo=&nlr=&nls=&sid=5208be89f9d87c58f9f838563e850eb9&sot=aff&sdt=cl&cluster=scopubyr%2c%222000%22%2ct&sl=189&s=AF-ID%28%22Universidad+Catolica+de+Cordoba%22+60024640%29+OR+AF-ID%28%22Universidad+Catolica+de+Cordoba++Facultad+de+Medicina%22+60015106%29+OR+AF-ID%28%22Clinica+Universitaria+Privada+Reina+Fabiola%22+60080337%29&relpos=4&citeCnt=4&searchTerm= |
| institution |
Universidad Católica de Córdoba |
| institution_str |
I-38 |
| repository_str |
R-144 |
| collection |
Producción Académica Universidad Católica de Córdoba (UCCor) |
| language |
Español |
| orig_language_str_mv |
spa |
| topic |
RE Oftalmología |
| spellingShingle |
RE Oftalmología Urrets Zavalía, Julio Urrets Zavalía, Enrique Alberto Iros, M. Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity |
| topic_facet |
RE Oftalmología |
| description |
Purpose: To present our experience of slit-lamp laser photocoagulation with a pediatric quadraspheric contact lens for the treatment of retinopathy of prematurity (ROP). Material and methods: 8 eyes of 4 premature babies with threshold ROP were consecutively treated under general anesthesia by means of blue-green argon laser photocoagulation delivered through a table mounted slit-lamp and a wide field contact lens specially designed for infants. Three of the treated eyes had a zone, disease, 2 a posterior zone II disease and 3 a zone II disease. Mean follow-up was 13 months. Results: Early complete regression of the neovascular proliferations and plus disease was observed in all the treated eyes (100%) without apparent sequela. In only one eye that had zone I disease a mild and small peripheral vitreous hemorrhage was observed. Neither cataract nor posterior synechia was observed. A discrete and transient badly hypothermia occurred only in one case. Comments and conclusions: This study shows the efficacy and precision of slit-lamp argon laser photocoagulation through a quadraspheric contact lens in ROP, with a very low rate of complications, and with a magnificent and comfortable visualization of all the structures to be treated. Each retinal burn was easily and very precisely placed from the ridge to the ora serrata in 360°with only a slight to moderate tilting of the wide field lens and without the need of scleral depression. |
| format |
Artículo |
| author |
Urrets Zavalía, Julio Urrets Zavalía, Enrique Alberto Iros, M. |
| author_facet |
Urrets Zavalía, Julio Urrets Zavalía, Enrique Alberto Iros, M. |
| author_sort |
Urrets Zavalía, Julio |
| title |
Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity |
| title_short |
Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity |
| title_full |
Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity |
| title_fullStr |
Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity |
| title_full_unstemmed |
Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity |
| title_sort |
slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity |
| publishDate |
2000 |
| url |
http://pa.bibdigital.ucc.edu.ar/3917/1/A_UrretsZavalia_UrretsZavalia_Iros.pdf |
| work_keys_str_mv |
AT urretszavaliajulio slitlamplaserphotocoagulationwithaquadrasphericcontactlensforthetreatmentofretinopathyofprematurity AT urretszavaliaenriquealberto slitlamplaserphotocoagulationwithaquadrasphericcontactlensforthetreatmentofretinopathyofprematurity AT irosm slitlamplaserphotocoagulationwithaquadrasphericcontactlensforthetreatmentofretinopathyofprematurity |
| _version_ |