Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity

Purpose: To present our experience of slit-lamp laser photocoagulation with a pediatric quadraspheric contact lens for the treatment of retinopathy of prematurity (ROP). Material and methods: 8 eyes of 4 premature babies with threshold ROP were consecutively treated under general anesthesia by means...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Urrets Zavalía, Julio, Urrets Zavalía, Enrique Alberto, Iros, M.
Formato: Artículo
Lenguaje:Español
Publicado: 2000
Materias:
Acceso en línea:http://pa.bibdigital.ucc.edu.ar/3917/1/A_UrretsZavalia_UrretsZavalia_Iros.pdf
Aporte de:
id I38-R144-3917
record_format dspace
spelling I38-R144-39172025-04-14T19:49:09Z http://pa.bibdigital.ucc.edu.ar/3917/ Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity Urrets Zavalía, Julio Urrets Zavalía, Enrique Alberto Iros, M. RE Oftalmología Purpose: To present our experience of slit-lamp laser photocoagulation with a pediatric quadraspheric contact lens for the treatment of retinopathy of prematurity (ROP). Material and methods: 8 eyes of 4 premature babies with threshold ROP were consecutively treated under general anesthesia by means of blue-green argon laser photocoagulation delivered through a table mounted slit-lamp and a wide field contact lens specially designed for infants. Three of the treated eyes had a zone, disease, 2 a posterior zone II disease and 3 a zone II disease. Mean follow-up was 13 months. Results: Early complete regression of the neovascular proliferations and plus disease was observed in all the treated eyes (100%) without apparent sequela. In only one eye that had zone I disease a mild and small peripheral vitreous hemorrhage was observed. Neither cataract nor posterior synechia was observed. A discrete and transient badly hypothermia occurred only in one case. Comments and conclusions: This study shows the efficacy and precision of slit-lamp argon laser photocoagulation through a quadraspheric contact lens in ROP, with a very low rate of complications, and with a magnificent and comfortable visualization of all the structures to be treated. Each retinal burn was easily and very precisely placed from the ridge to the ora serrata in 360°with only a slight to moderate tilting of the wide field lens and without the need of scleral depression. 2000-04-30 info:eu-repo/semantics/article info:eu-repo/semantics/closedAccess application/pdf spa http://pa.bibdigital.ucc.edu.ar/3917/1/A_UrretsZavalia_UrretsZavalia_Iros.pdf Urrets Zavalía, Julio ORCID: https://orcid.org/0000-0003-2267-2783 <https://orcid.org/0000-0003-2267-2783>, Urrets Zavalía, Enrique Alberto and Iros, M. (2000) Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity. Journal Francais d'Ophtalmologie, 23 (4). pp. 361-363. ISSN 0181-5512 https://www.scopus.com/record/display.uri?eid=2-s2.0-0034042399&origin=resultslist&sort=plf-f&src=s&nlo=&nlr=&nls=&sid=5208be89f9d87c58f9f838563e850eb9&sot=aff&sdt=cl&cluster=scopubyr%2c%222000%22%2ct&sl=189&s=AF-ID%28%22Universidad+Catolica+de+Cordoba%22+60024640%29+OR+AF-ID%28%22Universidad+Catolica+de+Cordoba++Facultad+de+Medicina%22+60015106%29+OR+AF-ID%28%22Clinica+Universitaria+Privada+Reina+Fabiola%22+60080337%29&relpos=4&citeCnt=4&searchTerm=
institution Universidad Católica de Córdoba
institution_str I-38
repository_str R-144
collection Producción Académica Universidad Católica de Córdoba (UCCor)
language Español
orig_language_str_mv spa
topic RE Oftalmología
spellingShingle RE Oftalmología
Urrets Zavalía, Julio
Urrets Zavalía, Enrique Alberto
Iros, M.
Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
topic_facet RE Oftalmología
description Purpose: To present our experience of slit-lamp laser photocoagulation with a pediatric quadraspheric contact lens for the treatment of retinopathy of prematurity (ROP). Material and methods: 8 eyes of 4 premature babies with threshold ROP were consecutively treated under general anesthesia by means of blue-green argon laser photocoagulation delivered through a table mounted slit-lamp and a wide field contact lens specially designed for infants. Three of the treated eyes had a zone, disease, 2 a posterior zone II disease and 3 a zone II disease. Mean follow-up was 13 months. Results: Early complete regression of the neovascular proliferations and plus disease was observed in all the treated eyes (100%) without apparent sequela. In only one eye that had zone I disease a mild and small peripheral vitreous hemorrhage was observed. Neither cataract nor posterior synechia was observed. A discrete and transient badly hypothermia occurred only in one case. Comments and conclusions: This study shows the efficacy and precision of slit-lamp argon laser photocoagulation through a quadraspheric contact lens in ROP, with a very low rate of complications, and with a magnificent and comfortable visualization of all the structures to be treated. Each retinal burn was easily and very precisely placed from the ridge to the ora serrata in 360°with only a slight to moderate tilting of the wide field lens and without the need of scleral depression.
format Artículo
author Urrets Zavalía, Julio
Urrets Zavalía, Enrique Alberto
Iros, M.
author_facet Urrets Zavalía, Julio
Urrets Zavalía, Enrique Alberto
Iros, M.
author_sort Urrets Zavalía, Julio
title Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
title_short Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
title_full Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
title_fullStr Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
title_full_unstemmed Slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
title_sort slit-lamp laser photocoagulation with a quadraspheric contact lens for the treatment of retinopathy of prematurity
publishDate 2000
url http://pa.bibdigital.ucc.edu.ar/3917/1/A_UrretsZavalia_UrretsZavalia_Iros.pdf
work_keys_str_mv AT urretszavaliajulio slitlamplaserphotocoagulationwithaquadrasphericcontactlensforthetreatmentofretinopathyofprematurity
AT urretszavaliaenriquealberto slitlamplaserphotocoagulationwithaquadrasphericcontactlensforthetreatmentofretinopathyofprematurity
AT irosm slitlamplaserphotocoagulationwithaquadrasphericcontactlensforthetreatmentofretinopathyofprematurity
_version_ 1832592400847994880