Analysis of the Impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests
"In this paper, the common-mode to differential mode conversion in a Bulk Current Injection (BCI) test setup is analyzed in the presence of an optical fiber transmitter. A modular-basis analysis based on S-parameters measurements and Electromagnetic simulations has been performed. It is shown t...
Guardado en:
Autores principales: | , |
---|---|
Formato: | acceptedVersion |
Lenguaje: | Inglés |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://ri.itba.edu.ar/handle/123456789/3990 |
Aporte de: |
id |
I32-R138-123456789-3990 |
---|---|
record_format |
dspace |
spelling |
I32-R138-123456789-39902022-12-07T13:05:49Z Analysis of the Impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests Gardella, Pablo Marini, Eduardo CONVERTIDORES ANALOGICO-DIGITALES "In this paper, the common-mode to differential mode conversion in a Bulk Current Injection (BCI) test setup is analyzed in the presence of an optical fiber transmitter. A modular-basis analysis based on S-parameters measurements and Electromagnetic simulations has been performed. It is shown that the loading effects can change the insertion losses from the RF amplifier to the Devices Under Test, even at frequencies as low as 10MHz by 2dB and up to 23dB at worst cases. The study has been undertaken with the substitution and closed-loop methods. Quantification of this problem as well as mitigation strategies are proposed, analyzed and evaluated with the aim of improving the accuracy of BCI simulations at early-design stages. Considering the significant cost of redesigning at an advanced point in the product development cycle, the presented work expects to raise awareness about how even small changes in the BCI setup can remarkably compromise the outcome." 2022-11-11T16:50:24Z 2022-11-11T16:50:24Z 2021 info:eu-repo/semantics/acceptedVersion https://ri.itba.edu.ar/handle/123456789/3990 en info:eu-repo/semantics/altIdentifier/doi/10.1109/emc/si/pi/emceurope52599.2021.9559253 application/pdf |
institution |
Instituto Tecnológico de Buenos Aires (ITBA) |
institution_str |
I-32 |
repository_str |
R-138 |
collection |
Repositorio Institucional Instituto Tecnológico de Buenos Aires (ITBA) |
language |
Inglés |
topic |
CONVERTIDORES ANALOGICO-DIGITALES |
spellingShingle |
CONVERTIDORES ANALOGICO-DIGITALES Gardella, Pablo Marini, Eduardo Analysis of the Impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests |
topic_facet |
CONVERTIDORES ANALOGICO-DIGITALES |
description |
"In this paper, the common-mode to differential mode conversion in a Bulk Current Injection (BCI) test setup is analyzed in the presence of an optical fiber transmitter. A modular-basis analysis based on S-parameters measurements and Electromagnetic simulations has been performed. It is shown that
the loading effects can change the insertion losses from the RF amplifier to the Devices Under Test, even at frequencies as low as 10MHz by 2dB and up to 23dB at worst cases. The study has been undertaken with the substitution and closed-loop methods. Quantification of this problem as well as mitigation strategies are proposed, analyzed and evaluated with the aim of improving the accuracy of BCI simulations at early-design stages. Considering the significant cost of redesigning at an advanced point in the product development cycle, the presented work expects to raise awareness about how even small changes in the BCI setup can
remarkably compromise the outcome." |
format |
acceptedVersion |
author |
Gardella, Pablo Marini, Eduardo |
author_facet |
Gardella, Pablo Marini, Eduardo |
author_sort |
Gardella, Pablo |
title |
Analysis of the Impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests |
title_short |
Analysis of the Impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests |
title_full |
Analysis of the Impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests |
title_fullStr |
Analysis of the Impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests |
title_full_unstemmed |
Analysis of the Impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests |
title_sort |
analysis of the impact of the monitoring equipment on the common-mode to differential-mode conversion in bulk current injection tests |
publishDate |
2022 |
url |
https://ri.itba.edu.ar/handle/123456789/3990 |
work_keys_str_mv |
AT gardellapablo analysisoftheimpactofthemonitoringequipmentonthecommonmodetodifferentialmodeconversioninbulkcurrentinjectiontests AT marinieduardo analysisoftheimpactofthemonitoringequipmentonthecommonmodetodifferentialmodeconversioninbulkcurrentinjectiontests |
_version_ |
1765661059390111744 |