SINTITUL-4
Goniometry is a technique widely used in human Kinesiotherapy to evaluate articular angles and demostrated to be a very valuable tool. The authors carried out this work to establish if it is as useful in veterinary medicine to evaluate articular functionality and they chose the elbow joint due to it...
Autores principales: | , , , |
---|---|
Formato: | Artículo publishedVersion |
Lenguaje: | Español |
Publicado: |
Universidad de Buenos Aires. Facultad de Ciencias Veterinarias.
2008
|
Materias: | |
Acceso en línea: | http://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=pveterinaria/invet&cl=CL1&d=HWA_4921 https://repositoriouba.sisbi.uba.ar/gsdl/collect/pveterinaria/invet/index/assoc/HWA_4921.dir/4921.PDF |
Aporte de: |
id |
I28-R145-HWA_4921 |
---|---|
record_format |
dspace |
spelling |
I28-R145-HWA_49212024-11-05 SINTITUL-4 Goniometry is a technique widely used in human Kinesiotherapy to evaluate articular angles and demostrated to be a very valuable tool. The authors carried out this work to establish if it is as useful in veterinary medicine to evaluate articular functionality and they chose the elbow joint due to its complexity. 24 canine patients derived to the Physical Therapy Unit of the Veterinary Medicine Teaching Hospital of the Buenos Aires University, Argentine, with a diagnosis of traumatic elbow luxation and its corresponding surgical correction, were selected. During the first physical therapy session data were collected with the aid of a manual goniometer to evaluate bilateral elbow flexion ? extension range of motion, settling down the contralateral forelimb as a normal value for this patient. The same procedure was carried out on the sixteenth session by the same physiotherapist. For all comparisons Statistical analysis Wilcoxon test was used, observing that at the end of the sixteenth session although measurements do not arrive to the normal value of a healthy limb, but a consistent improvement was observed from the first session. We could establish that it supplies an objective criteria to document the progress of the rehabilitation. Fil: Mercado, M.C. Universidad de Buenos Aires. Facultad de Ciencias Veterinarias. Área Enfermedades Quirúrgicas. Buenos Aires, Argentina Fil: Gambarotta, M. Universidad de Buenos Aires. Facultad de Ciencias Veterinarias. Área Estadística. Buenos Aires, Argentina Fil: González, S. Universidad de Buenos Aires. Facultad de Ciencias Veterinarias. Área Enfermedades Quirúrgicas. Buenos Aires, Argentina Fil: Pallares, C. Universidad de Buenos Aires. Facultad de Ciencias Veterinarias. Área Enfermedades Quirúrgicas. Buenos Aires, Argentina Mercado M.C. Gambarotta, M. González, S. Pallares, C. 2008 La goniometría es una técnica muy utilizada en Kinesiología Humana para evaluar ángulos articulares. Los autores realizaron este trabajo con el objetivo de poder establecer si es tan útil en Medicina veterinaria para evaluar funcionalidad articular. Se eligió la articulación del codo canino debido a su complejidad. Fueron seleccionados 24 pacientes caninos derivados al Servicio de Fisioterapia del Hospital Escuela de la Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Argentina; con diagnóstico de luxación traumática de codo y resolución quirúrgica correspondiente, registrándose los datos de la primera sesión de fisioterapia con un goniómetro manual para evaluar el rango de movilidad de flexión-extensión de codo bilateral, estableciéndose el miembro contralateral, como valor normal para dicho paciente. El mismo procedimiento fue llevado a cabo en la decimosexta sesión de fisioterapia y por el mismo fisioterapeuta. Para el análisis estadístico se utilizó el test de Wilcoxon para todas las comparaciones, observándose que al término de la decimosexta sesión, si bien no se llega a los valores normales de un miembro sano, existe registro de evolución favorable con respecto a la primera sesión fisioterápica. Se estableció que proporciona un criterio objetivo para documentar el progreso de la rehabilitación. application/pdf 1514-6634 (impreso) 1668-3498 (en línea) goniometría articulación codo caninos luxación goniometry elbow joint canine luxation spa Universidad de Buenos Aires. Facultad de Ciencias Veterinarias. info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ InVet, vol. 10, nº2 Utilidad de la goniometría en la evaluación del rango de los movimientos de flexión y extensión de la articulación del codo canino The useful of goniometry to evaluate the range of the elbow flexion and extension in dogs info:eu-repo/semantics/article info:ar-repo/semantics/artículo info:eu-repo/semantics/publishedVersion http://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=pveterinaria/invet&cl=CL1&d=HWA_4921 https://repositoriouba.sisbi.uba.ar/gsdl/collect/pveterinaria/invet/index/assoc/HWA_4921.dir/4921.PDF |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-145 |
collection |
Repositorio Digital de la Universidad de Buenos Aires (UBA) |
language |
Español |
orig_language_str_mv |
spa |
topic |
goniometría articulación codo caninos luxación goniometry elbow joint canine luxation |
spellingShingle |
goniometría articulación codo caninos luxación goniometry elbow joint canine luxation Mercado M.C. Gambarotta, M. González, S. Pallares, C. SINTITUL-4 |
topic_facet |
goniometría articulación codo caninos luxación goniometry elbow joint canine luxation |
description |
Goniometry is a technique widely used in human Kinesiotherapy to evaluate articular angles and demostrated to be a very valuable tool. The authors carried out this work to establish if it is as useful in veterinary medicine to evaluate articular functionality and they chose the elbow joint due to its complexity. 24 canine patients derived to the Physical Therapy Unit of the Veterinary Medicine Teaching Hospital of the Buenos Aires University, Argentine, with a diagnosis of traumatic elbow luxation and its corresponding surgical correction, were selected. During the first physical therapy session data were collected with the aid of a manual goniometer to evaluate bilateral elbow flexion ? extension range of motion, settling down the contralateral forelimb as a normal value for this patient. The same procedure was carried out on the sixteenth session by the same physiotherapist. For all comparisons Statistical analysis Wilcoxon test was used, observing that at the end of the sixteenth session although measurements do not arrive to the normal value of a healthy limb, but a consistent improvement was observed from the first session. We could establish that it supplies an objective criteria to document the progress of the rehabilitation. |
format |
Artículo Artículo publishedVersion |
author |
Mercado M.C. Gambarotta, M. González, S. Pallares, C. |
author_facet |
Mercado M.C. Gambarotta, M. González, S. Pallares, C. |
author_sort |
Mercado M.C. |
title |
SINTITUL-4 |
title_short |
SINTITUL-4 |
title_full |
SINTITUL-4 |
title_fullStr |
SINTITUL-4 |
title_full_unstemmed |
SINTITUL-4 |
title_sort |
sintitul-4 |
publisher |
Universidad de Buenos Aires. Facultad de Ciencias Veterinarias. |
publishDate |
2008 |
url |
http://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=pveterinaria/invet&cl=CL1&d=HWA_4921 https://repositoriouba.sisbi.uba.ar/gsdl/collect/pveterinaria/invet/index/assoc/HWA_4921.dir/4921.PDF |
work_keys_str_mv |
AT mercadomc sintitul4 AT gambarottam sintitul4 AT gonzalezs sintitul4 AT pallaresc sintitul4 AT mercadomc utilidaddelagoniometriaenlaevaluaciondelrangodelosmovimientosdeflexionyextensiondelaarticulaciondelcodocanino AT gambarottam utilidaddelagoniometriaenlaevaluaciondelrangodelosmovimientosdeflexionyextensiondelaarticulaciondelcodocanino AT gonzalezs utilidaddelagoniometriaenlaevaluaciondelrangodelosmovimientosdeflexionyextensiondelaarticulaciondelcodocanino AT pallaresc utilidaddelagoniometriaenlaevaluaciondelrangodelosmovimientosdeflexionyextensiondelaarticulaciondelcodocanino AT mercadomc theusefulofgoniometrytoevaluatetherangeoftheelbowflexionandextensionindogs AT gambarottam theusefulofgoniometrytoevaluatetherangeoftheelbowflexionandextensionindogs AT gonzalezs theusefulofgoniometrytoevaluatetherangeoftheelbowflexionandextensionindogs AT pallaresc theusefulofgoniometrytoevaluatetherangeoftheelbowflexionandextensionindogs |
_version_ |
1824359806782144512 |