Aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas
This paper shows that the use of filters based on the discrete wavelet transform (DWT) improves the sensitivity of photoacoustic systems for measurement of trace gases under conditions of unfavorable signal-to-noise ratio (SNR). To achieve this goal, a filter based on Meyer's DWT was designed a...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | Artículo publishedVersion |
Lenguaje: | Español |
Publicado: |
Universidad de Buenos Aires. Facultad de Ingeniería
2018
|
Materias: | |
Acceso en línea: | https://elektron.fi.uba.ar/index.php/elektron/article/view/35 https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=35_oai |
Aporte de: |
id |
I28-R145-35_oai |
---|---|
record_format |
dspace |
spelling |
I28-R145-35_oai2025-06-26 González, Martín Germán Santiago, Guillermo Daniel Slezak, Verónica Peuriot, Alejandro 2018-05-09 This paper shows that the use of filters based on the discrete wavelet transform (DWT) improves the sensitivity of photoacoustic systems for measurement of trace gases under conditions of unfavorable signal-to-noise ratio (SNR). To achieve this goal, a filter based on Meyer's DWT was designed and tested with simulated and measured signals. For the measurements, a system for the detection of traces of sulfur hexafluoride in nitrogen using a pulsed CO2 laser was implemented. From the results it was obtained that the use of DWT had a very good performance for signals generated with low laser energies ( < 100 uJ) corrupted with impulsive electromagnetic noise. En este trabajo se muestra que la utilización de filtros basados en la transformada wavelet discreta (DWT) mejora la sensibilidad de sistemas fotoacústicos para medición de gases traza bajo condiciones de relación señal a ruido (SNR) desfavorables. Para lograr este objetivo se diseñó un filtro basado en la DWT de Meyer y se lo probó con senales simuladas y medidas. Para las mediciones se implementó un sistema para la detección de trazas de hexafluoruro de azufre en nitrógeno usando un láser pulsado de CO2. A partir de los resultados se obtuvo que el uso de DWT tuvo un muy buen desempeño para señales generadas con bajas energías láser (< 100 uJ) corrompidas con ruido impulsivo electromagnético. application/pdf https://elektron.fi.uba.ar/index.php/elektron/article/view/35 10.37537/rev.elektron.2.1.35.2018 spa Universidad de Buenos Aires. Facultad de Ingeniería https://elektron.fi.uba.ar/index.php/elektron/article/view/35/39 https://elektron.fi.uba.ar/index.php/elektron/article/view/35/152 info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by-nc-nd/4.0 Elektron; Vol 2, No 1 (2018) 2525-0159 Photoacoustic Spectroscopy; trace gases; wavelets Espectroscopía fotoacústica; gases traza; wavelets Aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion info:ar-repo/semantics/artículo https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=35_oai |
institution |
Universidad de Buenos Aires |
institution_str |
I-28 |
repository_str |
R-145 |
collection |
Repositorio Digital de la Universidad de Buenos Aires (UBA) |
language |
Español |
orig_language_str_mv |
spa |
topic |
Photoacoustic Spectroscopy; trace gases; wavelets Espectroscopía fotoacústica; gases traza; wavelets |
spellingShingle |
Photoacoustic Spectroscopy; trace gases; wavelets Espectroscopía fotoacústica; gases traza; wavelets González, Martín Germán Santiago, Guillermo Daniel Slezak, Verónica Peuriot, Alejandro Aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas |
topic_facet |
Photoacoustic Spectroscopy; trace gases; wavelets Espectroscopía fotoacústica; gases traza; wavelets |
description |
This paper shows that the use of filters based on the discrete wavelet transform (DWT) improves the sensitivity of photoacoustic systems for measurement of trace gases under conditions of unfavorable signal-to-noise ratio (SNR). To achieve this goal, a filter based on Meyer's DWT was designed and tested with simulated and measured signals. For the measurements, a system for the detection of traces of sulfur hexafluoride in nitrogen using a pulsed CO2 laser was implemented. From the results it was obtained that the use of DWT had a very good performance for signals generated with low laser energies ( < 100 uJ) corrupted with impulsive electromagnetic noise. |
format |
Artículo publishedVersion Artículo |
author |
González, Martín Germán Santiago, Guillermo Daniel Slezak, Verónica Peuriot, Alejandro |
author_facet |
González, Martín Germán Santiago, Guillermo Daniel Slezak, Verónica Peuriot, Alejandro |
author_sort |
González, Martín Germán |
title |
Aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas |
title_short |
Aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas |
title_full |
Aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas |
title_fullStr |
Aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas |
title_full_unstemmed |
Aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas |
title_sort |
aplicación de wavelets en la detección fotoacústica de gases traza con señales ruidosas |
publisher |
Universidad de Buenos Aires. Facultad de Ingeniería |
publishDate |
2018 |
url |
https://elektron.fi.uba.ar/index.php/elektron/article/view/35 https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=35_oai |
work_keys_str_mv |
AT gonzalezmartingerman aplicaciondewaveletsenladeteccionfotoacusticadegasestrazaconsenalesruidosas AT santiagoguillermodaniel aplicaciondewaveletsenladeteccionfotoacusticadegasestrazaconsenalesruidosas AT slezakveronica aplicaciondewaveletsenladeteccionfotoacusticadegasestrazaconsenalesruidosas AT peuriotalejandro aplicaciondewaveletsenladeteccionfotoacusticadegasestrazaconsenalesruidosas |
_version_ |
1840330307021045760 |