Trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme

We present a new photoacoustic gas-trace measurement setup, based on a chirped optical chopper. This method combines features of the resonant and pulsed techniques. To show the advantages of this setup, we carried out a comparison with the resonant method in samples of NO2 contained in a one-dimensi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Carreño Romano, Carlos, Perez Fogwill, German, Santiago, Guillermo D., Gonzalez, Martin G.
Formato: Artículo publishedVersion
Lenguaje:Español
Publicado: FIUBA 2018
Materias:
Acceso en línea:https://elektron.fi.uba.ar/elektron/article/view/34
https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=34_oai
Aporte de:
id I28-R145-34_oai
record_format dspace
spelling I28-R145-34_oai2026-02-11 Carreño Romano, Carlos Perez Fogwill, German Santiago, Guillermo D. Gonzalez, Martin G. 2018-05-17 We present a new photoacoustic gas-trace measurement setup, based on a chirped optical chopper. This method combines features of the resonant and pulsed techniques. To show the advantages of this setup, we carried out a comparison with the resonant method in samples of NO2 contained in a one-dimensional acoustic resonator. The results show the chirped technique allows carrying out short-term acquisitions with good signal-to-noise ratio. En este trabajo se presenta un nuevo esquema de medición para espectroscopía fotoacústica de gases traza basado en un esquema de excitación up-chirp. Esta forma combina las ventajas de los esquemas resonante y pulsado. Para mostrar el potencial de esta técnica se la comparó con un esquema de excitación resonante sobre la medición de muestras de dióxido de nitrógeno en aire contenidas en una resonador acústico de alumnio. Los resultados mostraron que la técnica chirp permite realizar mediciones de corta duración con muy buena relación señal a ruido. application/pdf text/html https://elektron.fi.uba.ar/elektron/article/view/34 10.37537/rev.elektron.2.1.34.2018 spa FIUBA https://elektron.fi.uba.ar/elektron/article/view/34/36 https://elektron.fi.uba.ar/elektron/article/view/34/146 Derechos de autor 2018 Martin Gonzalez Elektron Journal; Vol. 2 No. 1 (2018); 7-11 Revista Elektron; Vol. 2 Núm. 1 (2018); 7-11 Revista Elektron; v. 2 n. 1 (2018); 7-11 2525-0159 2525-0159 Photoacoustic spectroscopy trace gases chirp Espectroscopía fotoacústica gases traza chirp Trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme Detección de gases traza por técnica fotoacústica basada en un esquema de excitación chirp lineal info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=34_oai
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-145
collection Repositorio Digital de la Universidad de Buenos Aires (UBA)
language Español
orig_language_str_mv spa
topic Photoacoustic spectroscopy
trace gases
chirp
Espectroscopía fotoacústica
gases traza
chirp
spellingShingle Photoacoustic spectroscopy
trace gases
chirp
Espectroscopía fotoacústica
gases traza
chirp
Carreño Romano, Carlos
Perez Fogwill, German
Santiago, Guillermo D.
Gonzalez, Martin G.
Trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme
topic_facet Photoacoustic spectroscopy
trace gases
chirp
Espectroscopía fotoacústica
gases traza
chirp
description We present a new photoacoustic gas-trace measurement setup, based on a chirped optical chopper. This method combines features of the resonant and pulsed techniques. To show the advantages of this setup, we carried out a comparison with the resonant method in samples of NO2 contained in a one-dimensional acoustic resonator. The results show the chirped technique allows carrying out short-term acquisitions with good signal-to-noise ratio.
format Artículo
publishedVersion
author Carreño Romano, Carlos
Perez Fogwill, German
Santiago, Guillermo D.
Gonzalez, Martin G.
author_facet Carreño Romano, Carlos
Perez Fogwill, German
Santiago, Guillermo D.
Gonzalez, Martin G.
author_sort Carreño Romano, Carlos
title Trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme
title_short Trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme
title_full Trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme
title_fullStr Trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme
title_full_unstemmed Trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme
title_sort trace gases detection by photoacoustic technique based on a lineal chirp excitation scheme
publisher FIUBA
publishDate 2018
url https://elektron.fi.uba.ar/elektron/article/view/34
https://repositoriouba.sisbi.uba.ar/gsdl/cgi-bin/library.cgi?a=d&c=elektron&d=34_oai
work_keys_str_mv AT carrenoromanocarlos tracegasesdetectionbyphotoacoustictechniquebasedonalinealchirpexcitationscheme
AT perezfogwillgerman tracegasesdetectionbyphotoacoustictechniquebasedonalinealchirpexcitationscheme
AT santiagoguillermod tracegasesdetectionbyphotoacoustictechniquebasedonalinealchirpexcitationscheme
AT gonzalezmarting tracegasesdetectionbyphotoacoustictechniquebasedonalinealchirpexcitationscheme
AT carrenoromanocarlos detecciondegasestrazaportecnicafotoacusticabasadaenunesquemadeexcitacionchirplineal
AT perezfogwillgerman detecciondegasestrazaportecnicafotoacusticabasadaenunesquemadeexcitacionchirplineal
AT santiagoguillermod detecciondegasestrazaportecnicafotoacusticabasadaenunesquemadeexcitacionchirplineal
AT gonzalezmarting detecciondegasestrazaportecnicafotoacusticabasadaenunesquemadeexcitacionchirplineal
_version_ 1857042996076216320