Reproducibility and realibility of a 4-day HBPM protocol with and without first day measurements

HBPM guidelines state that morning and evening measurements should be recorded and, to improve stability, the first day of measurements should be discarded. Our objective was to assess the reproducibility and reliability of a 4-day HBPM protocol with and without first day measurements. We analyzed a...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Barochiner, Jessica, Cuffaro, Paula E., Aparicio, Lucas S., Elizondo, Cristina M., Giunta, Diego H., Rada, Marcelo A., Morales, Margarita S., Alfie, José, Galarza, Carlos R., Waisman, Gabriel D.
Formato: Artículo revista
Lenguaje:Español
Publicado: Universidad Nacional Cba. Facultad de Ciencias Médicas. Secretaria de Ciencia y Tecnología 2018
Materias:
Acceso en línea:https://revistas.unc.edu.ar/index.php/med/article/view/21450
Aporte de:
id I10-R10article-21450
record_format ojs
institution Universidad Nacional de Córdoba
institution_str I-10
repository_str R-10
container_title_str Revistas de la UNC
language Español
format Artículo revista
topic home blood pressure
reproducibility
reliability
monitoreo domiciliario de presión arterial
reproducibilidad
confiabilidad
spellingShingle home blood pressure
reproducibility
reliability
monitoreo domiciliario de presión arterial
reproducibilidad
confiabilidad
Barochiner, Jessica
Cuffaro, Paula E.
Aparicio, Lucas S.
Elizondo, Cristina M.
Giunta, Diego H.
Rada, Marcelo A.
Morales, Margarita S.
Alfie, José
Galarza, Carlos R.
Waisman, Gabriel D.
Reproducibility and realibility of a 4-day HBPM protocol with and without first day measurements
topic_facet home blood pressure
reproducibility
reliability
monitoreo domiciliario de presión arterial
reproducibilidad
confiabilidad
author Barochiner, Jessica
Cuffaro, Paula E.
Aparicio, Lucas S.
Elizondo, Cristina M.
Giunta, Diego H.
Rada, Marcelo A.
Morales, Margarita S.
Alfie, José
Galarza, Carlos R.
Waisman, Gabriel D.
author_facet Barochiner, Jessica
Cuffaro, Paula E.
Aparicio, Lucas S.
Elizondo, Cristina M.
Giunta, Diego H.
Rada, Marcelo A.
Morales, Margarita S.
Alfie, José
Galarza, Carlos R.
Waisman, Gabriel D.
author_sort Barochiner, Jessica
title Reproducibility and realibility of a 4-day HBPM protocol with and without first day measurements
title_short Reproducibility and realibility of a 4-day HBPM protocol with and without first day measurements
title_full Reproducibility and realibility of a 4-day HBPM protocol with and without first day measurements
title_fullStr Reproducibility and realibility of a 4-day HBPM protocol with and without first day measurements
title_full_unstemmed Reproducibility and realibility of a 4-day HBPM protocol with and without first day measurements
title_sort reproducibility and realibility of a 4-day hbpm protocol with and without first day measurements
description HBPM guidelines state that morning and evening measurements should be recorded and, to improve stability, the first day of measurements should be discarded. Our objective was to assess the reproducibility and reliability of a 4-day HBPM protocol with and without first day measurements. We analyzed a retrospective cohort of ambulatory patients who required a HBPM for diagnostic purposes or evaluation of treatment efficacy. A 4-day protocol was implemented, with daily duplicate measurements in the morning, afternoon and evening, using an OMRON 705 CP validated equipment. HBPM reproducibility was quantified by test-re-test correlations and standard deviation of differences (SDD) between BP measurements obtained during the entire 4 days, with and without exclusion of the first day. The reliability criterion was the stabilization of the mean and standard deviation (SD). We included 353 subjects with a total of 8224 BP recordings (median of 24 recordings per patient). We found a strong test-re-test correlation between days 1 to 4, which improved when we excluded the first day (p<0.001). We also found a reduction of the mean BP when we increased the number of days and a reduction of SDD when we excluded day 1. Therefore, we conclude that the exclusion of the first day of measurements improves the reproducibility and reliability of a 4-day protocol, and such two factors are not affected by the inclusion of afternoon measurements.
publisher Universidad Nacional Cba. Facultad de Ciencias Médicas. Secretaria de Ciencia y Tecnología
publishDate 2018
url https://revistas.unc.edu.ar/index.php/med/article/view/21450
work_keys_str_mv AT barochinerjessica reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT cuffaropaulae reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT apariciolucass reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT elizondocristinam reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT giuntadiegoh reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT radamarceloa reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT moralesmargaritas reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT alfiejose reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT galarzacarlosr reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT waismangabrield reproducibilityandrealibilityofa4dayhbpmprotocolwithandwithoutfirstdaymeasurements
AT barochinerjessica reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT cuffaropaulae reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT apariciolucass reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT elizondocristinam reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT giuntadiegoh reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT radamarceloa reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT moralesmargaritas reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT alfiejose reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT galarzacarlosr reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
AT waismangabrield reproducibilidadyconfiabilidaddeunprotocolode4diasdemonitoreodomiciliariodepresionarterialconysinexclusiondelprimerdia
bdutipo_str Revistas
_version_ 1764819782049202176