Caracterización de tensiómetro multicámaras : protocolo

La presión arterial, aun en un organismo sano, depende de múltiples factores que van desde las condiciones ambientales al estado emocional del sujeto. Por otro lado, la presión arterial es una herramienta clínica fundamental para complementar el diagnóstico de un sinnúmero de enfermedades. Es esenci...

Descripción completa

Detalles Bibliográficos
Autores principales: Arena, Lucía Elizabeth (Autor, autor), Caranti, Giorgio Mario (autor), Rodríguez Aranciva, R. (autor), Mac Garry, N. F. (autor)
Formato: Capítulo de libro
Lenguaje:Español
Publicado: Villa Martelli, Buenos Aires : Asociación Física Argentina, 2011
Materias:
Acceso en línea:Registro en la Biblioteca Digital
PDF
Handle
DOI
Aporte de:Registro referencial: Solicitar el recurso aquí
LEADER 07061naa a22005777a 4500
003 AR-BaUEN
005 20230802145530.0
008 220707s2011 ag ado|fo|||| 000 0 spa d
022 |a 1850-1168 
040 |a AR-BaUEN  |b spa 
041 0 |b spa  |b eng 
044 |a ag 
100 1 |4 aut  |a Arena, Lucía Elizabeth  |e autor  |g arena@famaf.unc.edu.ar  |u Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física (UNC-FaMAF). Córdoba. Argentina 
245 1 0 |a Caracterización de tensiómetro multicámaras :   |b protocolo 
246 3 1 |a Characterization of multichambers tensiometer :   |b protocol 
260 |a Villa Martelli, Buenos Aires :  |b Asociación Física Argentina,  |c 2011 
270 |m arena@famaf.unc.edu.ar  |z Correo electrónico del Autor de correspondencia 
300 |a p. 74-78 :   |b il., fotos, gráfs. 
504 |a Referencias bibliográficas. 
506 |2 openaire  |e Acuerdo editorial  |f info:eu-repo/semantics/openAccess 
518 |o Fecha de publicación en la Biblioteca Digital FCEN-UBA  |d 2023-03-23 
520 3 |a La presión arterial, aun en un organismo sano, depende de múltiples factores que van desde las condiciones ambientales al estado emocional del sujeto. Por otro lado, la presión arterial es una herramienta clínica fundamental para complementar el diagnóstico de un sinnúmero de enfermedades. Es esencial contar con un muy buen instrumento de medición. En general, los métodos indirectos por auscultación son preferibles a los oscilométricos, pero aun los tensiómetros por auscultación tienen errores sistemáticos cuando se los compara con las mediciones directas de presión arterial realizados por el método invasivo (transductor de presión conectado a una línea arterial). Estudios realizados en los últimos años indican que los tensiómetros con brazaletes con cámaras múltiples, que se adecuan mejor al tamaño de brazo, son más exactos, es decir, los valores obtenidos con estos tensiómetros multicámaras son más representativos de la presión arterial medida por el método invasivo. En el presente trabajo se caracteriza la exactitud y precisión de un tensiómetro multicámara y se discute el protocolo implementado para estudiar su validez. Para ello se comparan las mediciones de presión arterial tomadas por auscultación con el tensiómetro multicámaras TMU-2, y un tensiómetro clásico de una cámara y por el método invasivo en 8 pacientes estabilizados (con un promedio de 10 registros cada uno). A partir del análisis estadístico realizado, tomando como patrón las presiones arteriales medidas por método invasivo, se tiene que las presiones sistólicas y diastólicas obtenidas con el tensiómetro multicámarasTMU-2 se apartan de los valores de presión invasivos unos 7 mmHg máximo, que es la mitad del apartamiento observado con tensiómetro clásico. Estos resultados indican que el TMU-2 cumple con los protocolos internacionales de validación de los dispositivos automáticos de medición de la presión arterial. A pesar de que el número de pacientes estudiado es bajo y que es importante ampliar el rango de las presiones arteriales a estudiar, los resultados dan mayor efectividad al tensiómetro multicámaras TMU-2 que al clásico de una única cámara  |l spa 
520 3 |a Blood pressure, even in a healthy life depends on many factors ranging from environmental conditions at the subject's emotional state. On the other hand, blood pressure is a key clinical tool to complement the diagnosis of a number of diseases. It is essential to have a very good measuring instrument. In general, indirect methods are preferred to auscultation oscillometric blood pressure but by auscultation even have systematic errors when compared with direct measurements of blood pressure made by the invasive method (pressure transducer connected to an arterial line). Studies in recent years indicate that the option of tensiometers with multi chambers bracelets, to fit more exactly the type of arm, are more efficient, ie, are more representative of the blood pressure measured by invasive method. In this work, the accuracy and precision of a multichambers tensiometer are characterized and the protocol implemented to study the validity of multi tensiometer.is dicussed. The blood pressure measurements taken by auscultation by a TMU-2 multichambers tensiometer, and the blood pressure of a classical cuff are compared with the invasive method pressure in 8 patients stabilized (with an average of 10 entries each one) From statistical analysis, taking blood pressures measured by invasive method as the pattern, the systolic and diastolic blood pressure obtained with multichambers TMU-2 deviate from invasive pressure values around 7 mmHg maximum, which is half the observed with classic tensiometer. These results indicate that TMU-2 meets international validation protocols for blood pressure automatic devices measuring. Although the number of patients studied is low and that is important to extend the range of blood pressures studied, these results indicate that multichambers tensiometer TMU-2 is more effective than a classic tensiometer of only one chamber  |l eng 
540 |2 cc  |f https://creativecommons.org/licenses/by-nc-sa/2.5/ar 
653 1 0 |a PRESION ARTERIAL 
653 1 0 |a ESFIGMOMANOMETRO 
653 1 0 |a TENSIOMETRO 
653 1 0 |a MANGO 
653 1 0 |a MULTICAMARAS 
653 1 0 |a INTRAARTERIAL 
690 1 0 |a BLOOD PRESSURE CUFF 
690 1 0 |a ESFIGMOMANOMETER 
690 1 0 |a CUFF 
690 1 0 |a BLOOD PRESSURE 
690 1 0 |a MULTICHAMBER 
690 1 0 |a INTRAARTERIAL 
700 1 |4 aut  |a Caranti, Giorgio Mario  |e autor  |u Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física (UNC-FaMAF). Córdoba. Argentina 
700 1 |4 aut  |a Rodríguez Aranciva, R.  |e autor  |u Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física (UNC-FaMAF). Córdoba. Argentina 
700 1 |4 aut  |a Mac Garry, N. F.  |e autor  |u Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física (UNC-FaMAF). Córdoba. Argentina 
773 0 |d Villa Martelli, Buenos Aires. Asociación Física Argentina,   |g v. 23  |h pp. 74-78  |k n. 01  |p An. (Asoc. Fís. Argent., En línea)  |w (AR-BaUEN)CENRE-9838  |x 1850-1168  |t Anales AFA 
856 4 1 |q application/pdf  |u https://bibliotecadigital.exactas.uba.ar/collection/afa/document/afa_v23_n01_p074  |x registro  |y Registro en la Biblioteca Digital 
856 4 1 |q application/pdf  |u https://bibliotecadigital.exactas.uba.ar/download/afa/afa_v23_n01_p074.pdf  |x derivado  |y PDF 
856 4 1 |q application/pdf  |u https://hdl.handle.net/20.500.12110/afa_v23_n01_p074  |x hdl  |y Handle 
856 4 1 |q application/pdf  |u https://doi.org/10.31527/analesafa.2014.23.1.74  |x doi  |y DOI 
901 |l 28  |m Juan Cristobal Sotomayor Chacon  |n 56678  |q Lucía Bongiovanni 
942 |c ASER  |n 0 
961 |a afa_v23_n01_p074  |b afa  |c PU  |e ND 
962 |a info:ar-repo/semantics/artículo  |a info:eu-repo/semantics/article  |b info:eu-repo/semantics/publishedVersion 
963 |a AA 
976 |a AEX 
999 |c 90405  |d 90405