Wall mass transfer coefficient in a trickle bed reactor

An electrochemical technique was used to measure the wall mass transfer coefficient in a trickle bed reactor in the pulsed-flow regime. Nitrogen-carboxymethyl cellulose solution was the system used and the influence of the liquid viscosity was studied. The instantaneous values of the coefficient sho...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Gabitto, Jorge Federico, Lemcoff, Norberto Oscar
Publicado: 1985
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03009467_v30_n1_p23_Gabitto
http://hdl.handle.net/20.500.12110/paper_03009467_v30_n1_p23_Gabitto
Aporte de:
Descripción
Sumario:An electrochemical technique was used to measure the wall mass transfer coefficient in a trickle bed reactor in the pulsed-flow regime. Nitrogen-carboxymethyl cellulose solution was the system used and the influence of the liquid viscosity was studied. The instantaneous values of the coefficient showed fluctuations with time and position but the average values were correlated by. Sh/Sc 1 3 = 4.97 Re0.24 The results were compared with heat transfer measurements carried out in previous work and satisfactory agreement is observed. © 1985.