Aberrations of spectrographs with the correction of the schmidt camera effected in the collimator

Of the different ways to introduce the Schmidt correction of the camera in a spectrograph, the case was studied in which it is effected in the collimator. Equations which describe the form of the wave-front at one side of the grating as function of the form at the other side were found. The sixthord...

Descripción completa

Guardado en:
Detalles Bibliográficos
Publicado: 1971
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00303909_v18_n11_p829_Simon
http://hdl.handle.net/20.500.12110/paper_00303909_v18_n11_p829_Simon
Aporte de:
id paper:paper_00303909_v18_n11_p829_Simon
record_format dspace
spelling paper:paper_00303909_v18_n11_p829_Simon2023-06-08T14:55:43Z Aberrations of spectrographs with the correction of the schmidt camera effected in the collimator Of the different ways to introduce the Schmidt correction of the camera in a spectrograph, the case was studied in which it is effected in the collimator. Equations which describe the form of the wave-front at one side of the grating as function of the form at the other side were found. The sixthorder terms in the correction to compensate for the deformation of the wavefront in the path from the collimator to the grating and to the mirror were also found. The aberrations for a correction which is symmetrical around the collimator axis were calculated. The limit of camera aperture for which these aberrations are tolerable is between F/D =4 and F/D=3 according to the size and number of lines of the grating. © 1971 Taylor & Francis Group, LLC. 1971 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00303909_v18_n11_p829_Simon http://hdl.handle.net/20.500.12110/paper_00303909_v18_n11_p829_Simon
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
description Of the different ways to introduce the Schmidt correction of the camera in a spectrograph, the case was studied in which it is effected in the collimator. Equations which describe the form of the wave-front at one side of the grating as function of the form at the other side were found. The sixthorder terms in the correction to compensate for the deformation of the wavefront in the path from the collimator to the grating and to the mirror were also found. The aberrations for a correction which is symmetrical around the collimator axis were calculated. The limit of camera aperture for which these aberrations are tolerable is between F/D =4 and F/D=3 according to the size and number of lines of the grating. © 1971 Taylor & Francis Group, LLC.
title Aberrations of spectrographs with the correction of the schmidt camera effected in the collimator
spellingShingle Aberrations of spectrographs with the correction of the schmidt camera effected in the collimator
title_short Aberrations of spectrographs with the correction of the schmidt camera effected in the collimator
title_full Aberrations of spectrographs with the correction of the schmidt camera effected in the collimator
title_fullStr Aberrations of spectrographs with the correction of the schmidt camera effected in the collimator
title_full_unstemmed Aberrations of spectrographs with the correction of the schmidt camera effected in the collimator
title_sort aberrations of spectrographs with the correction of the schmidt camera effected in the collimator
publishDate 1971
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00303909_v18_n11_p829_Simon
http://hdl.handle.net/20.500.12110/paper_00303909_v18_n11_p829_Simon
_version_ 1768544946711691264