Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects

The effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd2 O2 S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral compon...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Raspa, Verónica, Moreno, Cesar Hugo, Sigaut, Lorena
Publicado: 2007
Materias:
Acceso en línea:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00218979_v102_n12_p_Raspa
http://hdl.handle.net/20.500.12110/paper_00218979_v102_n12_p_Raspa
Aporte de:
id paper:paper_00218979_v102_n12_p_Raspa
record_format dspace
spelling paper:paper_00218979_v102_n12_p_Raspa2023-06-08T14:42:45Z Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects Raspa, Verónica Moreno, Cesar Hugo Sigaut, Lorena Estimation Image intensifiers (electron tube) Metal detectors Optimization Phosphors X ray radiography Flash radiography Mather-type tabletop plasma Metallic objects Phosphor intensifiers Plasma devices The effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd2 O2 S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral components in the 40-150 keV range, with a single maximum around 60-80 keV. The radiation output allows for 50 ns resolution, good contrast, and introspective imaging of metallic objects even through metallic walls. A numerical estimation of the induced voltage on the focus during the compressional stage is briefly discussed. © 2007 American Institute of Physics. Fil:Raspa, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Moreno, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Fil:Sigaut, L. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. 2007 https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00218979_v102_n12_p_Raspa http://hdl.handle.net/20.500.12110/paper_00218979_v102_n12_p_Raspa
institution Universidad de Buenos Aires
institution_str I-28
repository_str R-134
collection Biblioteca Digital - Facultad de Ciencias Exactas y Naturales (UBA)
topic Estimation
Image intensifiers (electron tube)
Metal detectors
Optimization
Phosphors
X ray radiography
Flash radiography
Mather-type tabletop plasma
Metallic objects
Phosphor intensifiers
Plasma devices
spellingShingle Estimation
Image intensifiers (electron tube)
Metal detectors
Optimization
Phosphors
X ray radiography
Flash radiography
Mather-type tabletop plasma
Metallic objects
Phosphor intensifiers
Plasma devices
Raspa, Verónica
Moreno, Cesar Hugo
Sigaut, Lorena
Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
topic_facet Estimation
Image intensifiers (electron tube)
Metal detectors
Optimization
Phosphors
X ray radiography
Flash radiography
Mather-type tabletop plasma
Metallic objects
Phosphor intensifiers
Plasma devices
description The effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd2 O2 S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral components in the 40-150 keV range, with a single maximum around 60-80 keV. The radiation output allows for 50 ns resolution, good contrast, and introspective imaging of metallic objects even through metallic walls. A numerical estimation of the induced voltage on the focus during the compressional stage is briefly discussed. © 2007 American Institute of Physics.
author Raspa, Verónica
Moreno, Cesar Hugo
Sigaut, Lorena
author_facet Raspa, Verónica
Moreno, Cesar Hugo
Sigaut, Lorena
author_sort Raspa, Verónica
title Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_short Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_full Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_fullStr Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_full_unstemmed Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_sort effective hard x-ray spectrum of a tabletop mather-type plasma focus optimized for flash radiography of metallic objects
publishDate 2007
url https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_00218979_v102_n12_p_Raspa
http://hdl.handle.net/20.500.12110/paper_00218979_v102_n12_p_Raspa
work_keys_str_mv AT raspaveronica effectivehardxrayspectrumofatabletopmathertypeplasmafocusoptimizedforflashradiographyofmetallicobjects
AT morenocesarhugo effectivehardxrayspectrumofatabletopmathertypeplasmafocusoptimizedforflashradiographyofmetallicobjects
AT sigautlorena effectivehardxrayspectrumofatabletopmathertypeplasmafocusoptimizedforflashradiographyofmetallicobjects
_version_ 1768542820506796032