New implantable devices for cardiovascular management and especially for heart failure

The concept of using a cardiac implantable device (CID) to manage arrhythmias and heart failure started over 50 years ago. Since then, we have seen these CID improve patient outcomes from bradyarrhythmias, atrial fibrillation, ventricular arrhythmias, and heart failure (HF). These devices are now st...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Marquez, L.L.L
Otros Autores: Bevacqua, R.J
Formato: Capítulo de libro
Lenguaje:Español
Publicado: Silver Horse SRL 2014
Acceso en línea:Registro en Scopus
Handle
Registro en la Biblioteca Digital
Aporte de:Registro referencial: Solicitar el recurso aquí
LEADER 30979caa a22016337a 4500
001 PAPER-24098
003 AR-BaUEN
005 20230518205553.0
008 190411s2014 xx ||||fo|||| 00| 0 spa|d
024 7 |2 scopus  |a 2-s2.0-84912069612 
040 |a Scopus  |b spa  |c AR-BaUEN  |d AR-BaUEN 
100 1 |a Marquez, L.L.L. 
245 1 0 |a New implantable devices for cardiovascular management and especially for heart failure 
246 3 1 |a Novos dispositivos implantáveis para o manejo cardiovascular e, especialmente, para a insuficiência cardíaca 
246 3 1 |a Nuevos dispositivos implantables para el manejo cardiovascular y especialmente para insuficiencia cardíaca 
260 |b Silver Horse SRL  |c 2014 
270 1 0 |m Bevacqua, R.J.; Domingo F. Sarmiento 3555 piso 1o “C”Argentina 
506 |2 openaire  |e Política editorial 
504 |a Ross, J.S., Chen, J., Lin, Z., Recent national trends in readmission rates after heart failure hospitalization (2010) Circ Heart Fail, 3, pp. 97-103 
504 |a Lloyd-Jones, D., Adams, R.J., Brown, T.M., Heart disease and stroke statistics 2010 update: A report from the American Heart Association (2010) Circulation, 121, pp. 146-215 
504 |a Jencks, S.F., Williams, M.V., Rehospitalizations among patients in the Medicare Fee-for-Service Program (2009) N Engl J Med, 360, pp. 1418-1428 
504 |a Russo, M.J., Gelijns, A.C., Stevenson, L.W., The cost of medical management in advanced heart failure during the final two years of life (2008) J Card Fail, 14, pp. 651-658 
504 |a Adams, K.F., Fonarow, G.C., Emerman, C.L., Characteristics and outcomes of patients hospitalized for heart failure in the United States: Rationale, design, and preliminary observations from the fi rst 100,000 cases in the Acute Decompensated Heart Failure National Registry (ADHERE) (2005) Am Heart J, 149, pp. 209-216 
504 |a Zile, M.R., Bennett, T.D., St John Sutton, M., Transition from chronic compensated to acute decompensated heart failure: Pathophysiological insights obtained from continuous monitoring of intracardiac pressures (2008) Circulation, 118, pp. 1433-1441 
504 |a Ritzema, J., Troughton, R., Melton, I., Physician-directed patient self-management of left atrial pressure in advanced chronic heart failure (2010) Circulation, 121, pp. 1086-1095 
504 |a Bourge, R.C., Abraham, W.T., Adamson, P.B., Aaron, M.F., Aranda, J.M., Jr, Magalski, A., Zile, M.R., Stevenson, L.W., COMPASS-HF Study Group. Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: The COMPASS-HF study (2008) J am Coll Cardiol, 51, pp. 1073-1079 
504 |a Chaudhry, S.I., Mattera, J.A., Curtis, J.P., Telemonitoring in patients with heart failure (2010) N Engl J Med, 363, pp. 2301-2309 
504 |a Lee, D.S., Krahn, A.D., Healey, J.S., Birnie, D., Crystal, E., Dorian, P., Simpson, C.S., Tu, J.V., Investigators of the Ontario ICD Database. Evaluation of early complications related to de novo cardioverter defibrillator implantation: Insights from the Ontario ICD database (2010) J am Coll Cardiol, 55, pp. 774-782 
504 |a Poole, J.E., Gleva, M.J., Mela, T., Chung, M.K., Uslan, D.Z., Borge, R., Gottipaty, V., Holcomb, R., REPLACE Registry Investigators. Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: Results from the REPLACE registry (2010) Circulation, 122, pp. 1553-1561 
504 |a Dekker, A.L., Phelps, B., Dijkman, B., Van Der Nagel, T., Van Der Veen, F.H., Geskes, G.G., Maessen, J.G., Epicardial left ventricular lead placement for cardiac resynchronization therapy: Optimal pace site selection with pressure-volume loops (2004) J Thorac Cardiovasc Surg, 127, pp. 1641-1647 
504 |a Spickler, J.W., Rasor, N.S., Kezdi, P., Misra, S.N., Robins, K.E., Leboeuf, C., Totally self-contained intracardiac pacemaker (1970) J Electrocardiol, 3, pp. 325-331 
504 |a Bonner, M.D., Eggen, M.D., Chronic animal study of leadless pacer design [abstract] (2011) Heart Rhythm, 8, p. S1 
504 |a Moulder, C., Whittington, H., Suwito, W., Kraetschmer, H., Muessig, D., Von Arx, J., Stotts, L., In vivo results of fully functional 1 cc leadless VVI pacemaker [abstract] (2012) Heart Rhythm, 9, p. S26 
504 |a Karami, M.A., Bradley, D.J., Inman, D.J., Vibration powered cardiac rhythm devices [abstract] (2012) Circulation, 126, p. A15551 
504 |a Goto, H., Sugiura, T., Harada, Y., Kazui, T., Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source (1999) Med Biol Eng Comput, 37, pp. 377-380 
504 |a Echt, D.S., Cowan, M.W., Riley, R.E., Brisken, A.F., Feasibility and safety of a novel technology for pacing without leads (2006) Heart Rhythm, 3, pp. 1202-1206 
504 |a Lee, K.L., Lau, C.P., Tse, H.F., Echt, D.S., Heaven, D., Smith, W., Hood, M., First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: Implications for wireless pacing with implantable devices (2007) J am Coll Cardiol, 50, pp. 877-883 
504 |a Lee, K.L., Tse, H.F., Echt, D.S., Lau, C.P., Temporary leadless pacing in heart failure patients with ultrasound-mediated stimulation energy and effects on the acoustic window (2009) Heart Rhythm, 6, pp. 742-748 
504 |a Echt, D.S., Moore, D., Cowan, M., Valli, V.E., Whitehair, J.G., Willis, N.P., Chronic implantation of leadless pacing electrodes in the left ventricle of a goat model [abstract] (2010) Heart Rhythm, 7, pp. S451-S452 
504 |a Wieneke, H., Konorza, T., Erbel, R., Kisker, E., Leadless pacing of the heart using induction technology: A feasibility study (2009) Pacing Clin Electrophysiol, 32, pp. 177-183 
504 |a Wieneke, H., Rickers, S., Velleuer, J., Bruck, G., Bai, Z., Kocks, C., Grandjean, P.A., Kisker, E., Leadless pacing using induction technology: Impact of pulse shape and geometric factors on pacing efficiency (2013) Europace, 15, pp. 453-459 
504 |a Leon, A.R., Abraham, W.T., Curtis, A.B., Daubert, J.P., Fisher, W.G., Gurley, J., Hayes, D.L., MIRACLE Study Program, Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure: Combined results of over 2,000 patients from a multicenter study program (2005) J am Coll Cardiol, 46, pp. 2348-2356 
504 |a Ellenbogen, K.A., Gold, M.R., Meyer, T.E., Fernandez Lozano, I., Mittal, S., Waggoner, A.D., Lemke, B., Stein, K.M., Primary results from the SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy (SMART-AV) trial: A randomized trial comparing empirical, echocardiography-guided, and algorithmic atrioventricular delay programming in cardiac resynchronization therapy (2010) Circulation, 122, pp. 2660-2668 
504 |a Khan, F.Z., Virdee, M.S., Palmer, C.R., Pugh, P.J., O’Halloran, D., Elsik, M., Read, P.A., Dutka, D.P., Targeted left ventricular lead placement to guide cardiac resynchronization therapy: The TARGET study: A randomized, controlled trial (2012) J am Coll Cardiol, 59, pp. 1509-1518 
504 |a Polasek, R., Kucera, P., Nedbal, P., Roubicek, T., Belza, T., Hanuliakova, J., Horak, D., Kautzner, J., Local electrogram delay recorded from left ventricular lead at implant predicts response to cardiac resynchronization therapy: Retrospective study with 1 year follow up (2012) BMC Cardiovasc Disord, 12, p. 34 
504 |a Singh, J.P., Klein, H.U., Huang, D.T., Reek, S., Kuniss, M., Quesada, A., Barsheshet, A., Moss, A.J., Left ventricular lead position and clinical outcome in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial (2011) Circulation, 123, pp. 1159-1166 
504 |a Nelson, K.E., Bates, M.G., Turley, A.J., Linker, N.J., Owens, W.A., Video-assisted thoracoscopic left ventricular pacing in patients with and without previous sternotomy (2013) Ann Thorac Surg, 95, pp. 907-913 
504 |a Burger, H., Kempfert, J., Van Linden, A., Szalay, Z., Schoenburg, M., Walther, T., Ziegelhoeffer, T., Endurance and performance of two different concepts for left ventricular stimulation with bipolar epicardial leads in long-term follow-up (2012) Thorac Cardiovasc Surg, 60, pp. 70-77 
504 |a Jais, P., Maury, P., Reddy, V.Y., Neuzil, P., Morgan, K., Bordachar, P., Ritter, P., Haissaquerre, M., Human implant feasibility of a novel epicardial pacing lead via non-surgical percutaneous subxiphoid approach [abstract] (2011) Heart Rhythm, 8, p. S1 
504 |a Strik, M., Rademakers, L.M., Van Deursen, C.J., Van Hunnik, A., Kuiper, M., Klersy, C., Auricchio, A., Prinzen, F.W., Endocardial left ventricular pacing improves cardiac resynchronization therapy in chronic asynchronous infarction and heart failure models (2012) Circ Arrhythm Electrophysiol, 5, pp. 191-200 
504 |a Van Deursen, C., Van Geldorp, I.E., Rademakers, L.M., Van Hunnik, A., Kuiper, M., Klersy, C., Auricchio, A., Prinzen, F.W., Endocardial left ventricular pacing improves cardiac resynchronization therapy in canine LBBB hearts (2009) Circ Arrhythm Electrophysiol, 2, pp. 580-587 
504 |a Spragg, D.D., Dong, J., Fetics, B.J., Helm, R., Marine, J.E., Cheng, A., Henrikson, C.A., Berger, R.D., Optimal left ventricular endocardial pacing sites for cardiac resynchronization therapy in patients with ischemic cardiomyopathy (2010) J am Coll Cardiol, 56, pp. 774-781 
504 |a Radbill, A.E., Triedman, J.K., Berul, C.I., Fynn-Thompson, F., Atallah, J., Alexander, M.E., Walsh, E.P., Cecchin, F., System survival of nontransvenous implantable cardioverter-defibrillators compared to transvenous implantable cardioverter-defibrillators in pediatric and congenital heart disease patients (2010) Heart Rhythm, 7, pp. 193-198 
504 |a Kowalski, M., Nicolato, P., Kalahasty, G., Kasirajan, V., Wood, M.A., Ellenbogen, K.A., Shepard, R.K., An alternative technique of implanting a nontransvenous implantable cardioverter-defibrillator system in adults with no or limited venous access to the heart (2010) Heart Rhythm, 7, pp. 1572-1577 
504 |a Maisel, W.H., Kramer, D.B., Implantable cardioverter-defibrillator lead performance (2008) Circulation, 117, pp. 2721-2723 
504 |a Van Rees, J.B., De Bie, M.K., Thijssen, J., Borleffs, C.J., Schalij, M.J., Van Erven, L., Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: A systematic review of randomized clinical trials (2011) J am Coll Cardiol, 58, pp. 995-1000 
504 |a Bardy, G.H., Smith, W.M., Hood, M.A., Crozier, I.G., Melton, I.C., Jordaens, L., Theuns, D., Grace, A.A., An entirely subcutaneous implantable cardioverter-defibrillator (2010) N Engl J Med, 363, pp. 36-44 
504 |a Gold, M.R., Theuns, D.A., Knight, B.P., Sturdivant, J.L., Sanghera, R., Ellenbogen, K.A., Wood, M.A., Burke, M.C., Head-to-head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: The START study (2012) J Cardiovasc Electrophysiol, 23, pp. 359-366 
504 |a Moss, A.J., Schuger, C., Beck, C.A., Brown, M.W., Cannom, D.S., Daubert, J.P., Estes, N.A., III, MADIT-RIT Trial Investigators, Reduction in inappropriate therapy and mortality through ICD programming (2012) N Engl J Med, 367, pp. 2275-2283 
504 |a Olde Nordkamp, L.R., Knops, R.E., Bardy, G.H., Blaauw, Y., Boersma, L.V., Bos, J.S., Delnoy, P.P., Wilde, A.A., Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy (2012) Am Heart J, 163, pp. 753-760 
504 |a Poole, J.E., Johnson, G.W., Hellkamp, A.S., Erson, J., Callans, D.J., Raitt, M.H., Reddy, R.K., Bardy, G.H., Prognostic importance of defibrillator shocks in patients with heart failure (2008) N Engl J Med, 359, pp. 1009-1017 
504 |a Li, W., Ripplinger, C.M., Lou, Q., Efimov, I.R., Multiple monophasic shocks chronic infarction (2009) Heart Rhythm, 6, pp. 1020-1027 
504 |a Li, W., Janardhan, A.H., Fedorov, V.V., Sha, Q., Schuessler, R.B., Efimov, I.R., Low-energy multistage atrial defibrillation therapy terminates atrial fibrillation with less energy than a single shock (2011) Circ Arrhythm Electrophysiol, 4, pp. 917-925 
504 |a Janardhan, A.H., Li, W., Fedorov, V.V., Yeung, M., Wallendorf, M.J., Schuessler, R.B., Efimov, I.R., A novel low-energy electrotherapy that terminates ventricular tachycardia with lower energy than a biphasic shock when antitachycardia pacing fails (2012) J am Coll Cardiol, 60, pp. 2393-2398 
504 |a Sweeney, M.O., Ruskin, J.N., Garan, H., McGovern, B.A., Guy, M.L., Torchiana, D.F., Vlahakes, G.J., Dec, G.W., Influence of the implantable cardioverter/defibrillator on sudden death and total mortality in patients evaluated for cardiac transplantation (1995) Circulation, 92, pp. 3273-3281 
504 |a Mitchell, L.B., Pineda, E.A., Titus, J.L., Bartosch, P.M., Benditt, D.G., Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation (2002) J am Coll Cardiol, 39, pp. 1323-1328 
504 |a Hulleman, M., Berdowski, J., De Groot, J.R., Van Dessel, P.F., Borleffs, C.J., Blom, M.T., Bardai, A., Koster, R.W., Implantable cardioverter-defibrillators have reduced the incidence of resuscitation for out-of-hospital cardiac arrest caused by lethal arrhythmias (2012) Circulation, 126, pp. 815-821 
504 |a Rosborough, J.P., Deno, D.C., Electrical therapy for post defibrillatory pulseless electrical activity (2004) Resuscitation, 63, pp. 65-72 
504 |a Wang, H., Tang, W., Tsai, M.S., Sun, S., Li, Y., Gilman, B., Kroll, M.W., Weil, M.H., Coronary blood flow produced by muscle contractions induced by intracardiac electrical CPR during ventricular fibrillation (2009) Pacing Clin Electrophysiol, 32, pp. S223-S227 
504 |a Gilman, B.L., Brewer, J.E., Kroll, K., Kroll, M.W., Medium voltage therapy for preventing and treating asystole and PEA in ICDs (2009) Conf Proc IEEE Eng Med Biol Soc 2009, pp. 4623-4625 
504 |a Rickard, J., Ahmed, S., Baruch, M., Klocman, B., Martin, D.O., Menon, V., Utility of a novel watch-based pulse detection system to detect pulselessness in human subjects (2011) Heart Rhythm, 8, pp. 1895-1899 
504 |a Cleven, N.J., Muntjes, J.A., Fassbender, H., Urban, U., Gortz, M., Vogt, H., Grafe, M., Mokwa, W., A novel fully implantable wireless sensor system for monitoring hypertension patients (2012) IEEE Trans Biomed Eng, 59, pp. 3124-3130 
504 |a Krunholz, H.M., Krumholz, H.M., Parent, E.M., Tu, N., Vaccarino, V., Wang, Y., Radford, M.J., Hennen, J., Readmission after hospitalization for congestive heart failure among Medicare beneficiaries (1997) Arch Intern Med, 157, pp. 99-104 
504 |a Stevenson, L.W., Perloff, J.K., The limited reliability of physical signs for estimating hemodynamics in chronic heart failure (1989) JAMA, 261, pp. 884-888 
504 |a Lobo Marquez, L.L., Manejo integrado de la insuficiencia cardiaca: Clinica y tecnologia. Vision de un cardiologo clinico (2013) Insuf Card, 8 (4), pp. 171-184 
504 |a Kadhiresan, V.A., Pastore, J., Auricchio, A., Sack, S., Doelger, A., Girouard, S., Spinelli, J.C., PATH-CHF Study Group, Pacing Therapies in Congestive Heart Failure. A novel method the activity log index for monitoring physical activity of patients with heart failure (2002) Am J Cardiol, 89, pp. 1435-1437 
504 |a Singh, J.P., Rosenthal, L.S., Hranitzky, P.M., Berg, K.C., Mullin, C.M., Thackeray, L., Kaplan, A., Device diagnostics and long-term clinical outcome in patients receiving cardiac resynchronization therapy (2009) Europace, 11, pp. 1647-1653 
504 |a Hopenfeld, B., John, M.S., Fischell, D.R., Medeiros, P., Guimaraes, H.P., Piegas, L.S., The Guardian: An implantable system for chronic ambulatory monitoring of acute myocardial infarction (2009) J Electrocardiol, 42, pp. 481-486 
504 |a Bevacqua, R.J., Monitoreo continuo del segmento ST a traves del electrograma intracardiaco por un dispositivo cardiaco implantable (2013) Insuf Card, 8 (1), pp. 31-40 
504 |a Forleo, G.B., Tesauro, M., Panattoni, G., Della Rocca, D.G., Papavasileiou, L.P., Sergi, D., Di Molfetta, A., Romeo, F., Impact of continuous intracardiac ST-segment monitoring on mid-term outcomes of ICD-implanted patients with coronary artery disease: Early results of a prospective comparison with conventional ICD outcomes (2012) Heart, 98, pp. 402-407 
504 |a Yu, C.M., Wang, L., Chau, E., Chan, R.H., Kong, S.L., Tang, M.O., Christensen, J., Lau, C.P., Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization (2005) Circulation, 112, pp. 841-848 
504 |a Benhayon, D., Impedancia transtoracica como herramienta para el manejo del paciente con insuficiencia cardiaca (2014) Insuf Card, 9 (1), pp. 48-52 
504 |a Van Veldhuisen, D.J., Braunschweig, F., Conraads, V., Ford, I., Cowie, M.R., Jondeau, G., Kautzner, J., DOT-HF Investigators, Intrathoracic impedance monitoring, audible patient alerts, and outcome in patients with heart failure (2011) Circulation, 124, pp. 1719-1726 
504 |a Binkley, P.F., Porterfield, J.G., Porterfield, L.M., Beau, S.L., Corbisiero, R., Greer, G.S., Love, C.J., Farazi, T.G., Feasibility of using multivector impedance to monitor pulmonary congestion in heart failure patients (2012) J Interv Card Electrophysiol, 35, pp. 197-206 
504 |a Proietti, R., Manzoni, G., Di Biase, L., Castelnuovo, G., Lombardi, L., Fundaro, C., Vegliante, N., Natale, A., Closed loop stimulation is effective in improving heart rate and blood pressure response to mental stress: Report of a single-chamber pacemaker study in patients with chronotropic incompetent atrial fibrillation (2012) Pacing Clin Electrophysiol, 35, pp. 990-998 
504 |a Bocchiardo, M., Meyer Zu Vilsendorf, D., Militello, C., Lippert, M., Czygan, G., Gaita, F., Schauerte, P., Stellbrink, C., Intracardiac impedance monitors stroke volume in resynchronization therapy patients (2010) Europace, 12, pp. 702-707 
504 |a Occhetta, E., Bortnik, M., Audoglio, R., Vassanelli, C., INVASY Study Investigators, Closed loop stimulation in prevention of vasovagal syncope: Inotropy Controlled Pacing in Vasovagal Syncope (INVASY): A multicentre randomized, single blind, controlled study (2004) Europace, 6, pp. 538-547 
504 |a Heist, E.K., Herre, J.M., Binkley, P.F., Van Bakel, A.B., Porterfield, J.G., Porterfield, L.M., Qu, F., DEFEAT-PE Study Investigators, Analysis of Different Device-Based Intrathoracic Impedance Vectors for Detection of Heart Failure Events (from the Detect Fluid Early from Intrathoracic Impedance Monitoring Study) (2014) Am J Cardiol, 114 (8), pp. 1249-1256 
504 |a Ohlsson, A., Kubo, S.H., Steinhaus, D., Connelly, D.T., Adler, S., Bitkover, C., Nordlander, R., Bennett, T., Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: Results of a 1 year multicentre feasibility study (2001) Eur Heart J, 22, pp. 942-954 
504 |a Delnoy, P.P., Marcelli, E., Oudeluttikhuis, H., Nicastia, D., Renesto, F., Cercenelli, L., Plicchi, G., Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: Early clinical results (2008) Europace, 10, pp. 801-808 
504 |a Steimle, A.E., Stevenson, L.W., Chelimsky-Fallick, C., Fonarow, G.C., Hamilton, M.A., Moriguchi, J.D., Kartashov, A., Tillisch, J.H., Sustained hemodynamic efficacy of therapy tailored to reduce filling pressures in survivors with advanced heart failure (1997) Circulation, 96, pp. 1165-1172 
504 |a Adamson, P.B., Gold, M.R., Bennett, T., Bourge, R.C., Stevenson, L.W., Trupp, R., Stromberg, K., Zile, M., Continuous hemodynamic monitoring in patients with mild to moderate heart failure: Results of the Reducing Decompensation Events Utilizing Intracardiac Pressures in Patients With Chronic Heart Failure (REDUCEhf) trial (2011) Congest Heart Fail, 17, pp. 248-254 
504 |a Abraham, W.T., Adamson, P.B., Bourge, R.C., Aaron, M.F., Costanzo, M.R., Stevenson, L.W., Strickland, W., Yadav, J.S., CHAMPION Trial Study Group. Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: A randomised controlled trial (2011) Lancet, 377, pp. 658-666 
504 |a Concepcion, R., Alcaino, M., Deck, C., Alfaro, M., Castro, P.F., Perrone, S.V., Primer implante de sensor inalambrico HeartSureR para monitoreo de presiones en arteria pulmonar de pacientes con insuficiencia cardiac (2006) Insuf Card, 1 (1), pp. 56-57 
504 |a Magalski, A., Adamson, P.B., Gadler, F., Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: A multicenter, 12-month follow-up study of patients with chronic heart failure (2002) J Card Fail, 8, pp. 63-70 
504 |a Verdejo, H.E., Castro, P.F., Concepcion, R., Comparison of a radiofrequency-based wireless pressure sensor to Swan-Ganz catheter and echocardiography for ambulatory assessment of pulmonary artery pressure in heart failure (2007) J am Coll Cardiol, 50, pp. 2375-2382 
504 |a Castro, P.F., Concepcion, R., Bourge, R.C., A wireless pressure sensor for monitoring pulmonary artery pressure in advanced heart failure: Initial experience (2007) J Heart Lung Transplant, 26, pp. 85-88 
504 |a Ritzema, J., Melton, I.C., Richards, A.M., Direct left atrial pressure monitoring in ambulatory heart failure patients: Initial experience with a new permanent implantable device (2007) Circulation, 116, pp. 2952-2959 
504 |a Adamson, P.B., Magalski, A., Braunschweig, F., Ongoing right ventricular hemodynamics in heart failure: Clinical value of measurements derived from an implantable monitoring system (2003) J am Coll Cardiol, 41, pp. 565-571 
504 |a Hoppe, U.C., Vanderheyden, M., Sievert, H., Chronic monitoring of pulmonary artery pressure in patients with severe heart failure: Multicentre experience of the monitoring Pulmonary Artery Pressure by Implantable device Responding to in patients Ultrasonic Signal (PAPIRUS) II study (2009) Heart, 95, pp. 1091-1097 
504 |a Hunt, S.A., Abraham, W.T., Chin, M.H., American College of Cardiology Foundation/American Heart Association 2009 focused update incorporated into the ACC/AHA 2005 guidelines for the diagnosis and management of heart failure in adults: A report of the American College of Cardiology Foundation/American Heart Association Task Force on practice guidelines developed in collaboration with the International Society for Heart and Lung Transplantation (2009) J am Coll Cardiol, 53, pp. 81-90 
504 |a Adamson, P.B., Abraham, W.T., Bourge, R.C., CHAMPION trial rationale and design: The long-term safety and clinical efficacy of a wireless pulmonary artery pressure monitoring system (2011) J Card Fail, 17, pp. 3-10 
504 |a Ritzema, J., Troughton, R., Melton, I., Crozier, I., Doughty, R., Krum, H., Walton, A., Abraham, W.T., Hemodynamically Guided Home Self-Therapy in Severe Heart Failure Patients (HOMEOSTASIS) Study Group. Physician-directed patient self-management of left atrial pressure in advanced chronic heart failure (2010) Circulation, 121, pp. 1086-1095 
504 |a Mercier, P.P., Lysaght, A.C., Bandyopadhyay, S., Chandrakasan, A.P., Stankovic, K.M., Energy extraction from the biologic battery in the inner ear (2012) Nat Biotechnol, 30, pp. 1240-1243 
504 |a Whellan, D.J., Ousdigian, K.T., Al-Khatib, S.M., Pu, W., Sarkar, S., Porter, C.B., Pavri, B.B., PARTNERS Study Investigators, Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: Results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) study (2010) J am Coll Cardiol, 55, pp. 1803-1810 
504 |a Altman, R.K., Parks, K.A., Schlett, C.L., Orencole, M., Park, M.Y., Truong, Q.A., Deeprasertkul, P., Singh, J.P., Multidisciplinary care of patients receiving cardiac resynchronization therapy is associated with improved clinical outcomes (2012) Eur Heart J, 33, pp. 2181-2188 
504 |a Swerdlow, C.D., Gunderson, B.D., Ousdigian, K.T., Abeyratne, A., Sachanandani, H., Ellenbogen, K.A., Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: A prospective study (2010) Circulation, 122, pp. 1449-1455 
504 |a Landolina, M., Perego, G.B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Marzegalli, M., Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators: The Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study (2012) Circulation, 125, pp. 2985-2992 
504 |a Varma, N., Epstein, A.E., Irimpen, A., Schweikert, R., Love, C., TRUST Investigators, Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T Safely Reduces Routine Office Device Follow-up (TRUST) trial (2010) Circulation, 122, pp. 325-332 
504 |a Healey, J.S., Connolly, S.J., Gold, M.R., Israel, C.W., Van Gelder, I.C., Capucci, A., Lau, C.P., ASSERT Investigators, Subclinical atrial fibrillation and the risk of stroke (2012) N Engl J Med, 366, pp. 120-129 
504 |a Ip, J., Waldo, A.L., Lip, G.Y., Rothwell, P.M., Martin, D.T., Bersohn, M.M., Choucair, W.K., IMPACT Investigators, Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohort: The IMPACT study (2009) Am Heart J, 158, pp. 364-370 
504 |a Verma, A., Champagne, J., Sapp, J., Essebag, V., Novak, P., Skanes, A., Morillo, C.A., Birnie, D., Discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation (DISCERN AF): A prospective, multicenter study (2013) JAMA Intern Med, 173, pp. 149-156 
504 |a Cotter, P.E., Martin, P.J., Ring, L., Warburton, E.A., Belham, M., Pugh, P.J., Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke (2013) Neurology, 80, pp. 1546-1550 
504 |a Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.H., Lebedev, D., Rieger, G., XPECT Trial Investigators, Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial (2010) Circ Arrhythm Electrophysiol, 3, pp. 141-147 
504 |a Bloch Thomsen, P.E., Jons, C., Raatikainen, M.J., Moerch Joergensen, R., Hartikainen, J., Virtanen, V., Boland, J., Huikuri, H.V., Cardiac Arrhythmias and Risk Stratification After Acute Myocardial Infarction (CARISMA) Study Group. Long-term recording of cardiac arrhythmias with an implantable cardiac monitor in patients with reduced ejection fraction after acute myocardial infarction: The Cardiac Arrhythmias and Risk Stratification After Acute Myocardial Infarction (CARISMA) study (2010) Circulation, 122, pp. 1258-1264 
504 |a Jons, C., Thomsen, P.E., Treating cardiac arrhythmias detected with an implantable cardiac monitor in patients after an acute myocardial infarction (2012) Curr Treat Options Cardiovasc Med, 14, pp. 39-49 
520 3 |a The concept of using a cardiac implantable device (CID) to manage arrhythmias and heart failure started over 50 years ago. Since then, we have seen these CID improve patient outcomes from bradyarrhythmias, atrial fibrillation, ventricular arrhythmias, and heart failure (HF). These devices are now standard of care in the management of patients and include pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy or This technology of implantable heart rhythm monitoring and therapeutic devices has only been established in the last few decades. Recent advances in such technology have led to simpler implantation techniques, greater patient convenience with smaller device sizes, leadless pacemakers, extended battery longevity, increased device safety and reliability, and improved clinical outcomes. Early detection of worsening HF by implantable sensors allows corrective therapy for acute decompensation. The future may hold expansion of the indications for these CID, with careful examination of the outcomes of today’s patients. In addition, there is very exciting new technology that may further advance the management of arrhythmias and HF. © 2014 Silver Horse.  |l eng 
593 |a Departamento de Insuficiencia Cardiaca e Hipertension pulmonar, Instituto de Cardiologia, San Miguel de Tucuman, Tucuman, Argentina 
593 |a Medico de Planta. Unidad Coronaria, Coordinador Residencia de Cardiologia, Instituto de Cardiologia. San Miguel de Tucuman, Tucuman, Argentina 
593 |a Comite de Insuficiencia Cardiaca de Federacion Argentina de Cardiologia, Argentina 
593 |a Division Cardiologia. Pabellon Inchauspe, Hospital General de Agudos “Dr. J. M. Ramos Mejia”. GCBA, Buenos Aires, Argentina 
690 1 0 |a CARDIAC ARRHYTHMIAS 
690 1 0 |a CARDIAC IMPLANTABLE DEVICES 
690 1 0 |a CARDIAC RESYNCHRONIZATION THERAPY 
690 1 0 |a DEFIBRILLATOR 
690 1 0 |a DEFIBRILLATOR 
690 1 0 |a HEART FAILURE 
690 1 0 |a IMPLANTABLE CARDIOVERTER 
690 1 0 |a LEADLESS PACEMAKER 
690 1 0 |a PACEMAKER 
690 1 0 |a SUBCUTANEOUS IMPLANTABLE CARDIOVERTER 
690 1 0 |a SUDDEN CARDIAC DEATH 
700 1 |a Bevacqua, R.J. 
773 0 |d Silver Horse SRL, 2014  |g v. 9  |h pp. 164-183  |k n. 4  |p Insuficiencia Cardiaca  |x 18501044  |w (AR-BaUEN)CENRE-8510  |t Insuficiencia Cardiaca 
856 4 1 |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-84912069612&partnerID=40&md5=8cc6264bb2798a22e0895baf152dc6fa  |y Registro en Scopus 
856 4 0 |u https://hdl.handle.net/20.500.12110/paper_18501044_v9_n4_p164_Marquez  |y Handle 
856 4 0 |u https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_18501044_v9_n4_p164_Marquez  |y Registro en la Biblioteca Digital 
961 |a paper_18501044_v9_n4_p164_Marquez  |b paper  |c PE 
962 |a info:eu-repo/semantics/article  |a info:ar-repo/semantics/artículo  |b info:eu-repo/semantics/publishedVersion